Recent content by Tarby25

  1. T

    Glowworm BG 330 boiler

    Well I'm sorry but you have caused offence ! I thought these forums were help imPart knowledge to others not to slate them for not knowing . I'm sorry I obviously wasn't born with the immense amount of information about fault finding the YOU obviously were ! You only learn by being taught . I...
  2. T

    Glowworm BG 330 boiler

    ok many thanks
  3. T

    Glowworm BG 330 boiler

    Thanks ratonastick. i fitted the pcb as instructed on the paperwork . Was a little confused about the jumper connection. But going throught the actual boilers paperwork there is no fan transformer on this boiler. G.C 41-047-75. This is a British gas boiler rather than a standard glowworm. I...
  4. T

    Glowworm BG 330 boiler

    And the point im trying to put across is that the pcb has been changed now and has cleared the f13 fault but after the start up of the boiler there is ignition but no combustion apart from a small puff of gas no full ignition.So was just asking for some advice to see whether someone else had...
  5. T

    Glowworm BG 330 boiler

    I am gas safe registered . but am not a wise old sage like some people and so dont have all knowledge about everything. so you are permitted to to give advice if you so wish.
  6. T

    Glowworm BG 330 boiler

    Hi im just after a little confirmation really . I had an f13 fault come up on this boiler ,checked all plugs and connections all ok so replaced the pcb , now im getting an f1 fault code, the boiler has a strong ignition spark and allows a small puff of gas through to the blast chamber but it...
  7. T

    Ideal icos :(

    Anyone please
  8. T

    Ideal icos :(

    Hi I wonder I'd you can help does anyone have any idea what the fault codes H & F mean on this boiler ? Thought it might be frozen condense but it runs internally to sink waste... Thanks in advance
  9. T

    programmer wiring

    thankyou kindly sir :)
  10. T

    programmer wiring

    ok what about the neutrals in No1 though
  11. T

    programmer wiring

    my bad .. yes three wires there is a wall stat , pump , 2 x 2 port valves, cylinder stat , boiler
  12. T

    programmer wiring

    fully pumped... pic is upside down
  13. T

    Comment by 'Tarby25' in media 'Untitled'

    picture is upside down so numbers go right to left
  14. Untitled

    Untitled

  15. bits

    bits

    bits
Back
Top