    Blauberg Aeris-Midi Decentralised Single Room Ductless Heat Recovery Unit

    Hi All, Does anyone have experience with this type of single room heat recovery units? Getting a lot of condensation in the bedrooms and seen these advertised. Retrofitting a full MVHR would be extremely difficult and expensive. We're in a flat roofed bungalow so not interested in a simple...
  2. T

    Intermediate Heat Exchanger

    Gasguru. You are welcome to pop by and opine/quote. I'm between Guildford and Horsham.
  3. T

    Intermediate Heat Exchanger

    Ok, I've had a look at the boiler faults and it looks like I'm getting a lot of F.23s and a few F.20s. I can't get into the menu to check settings - I have the user and install PDFs but it's not playing ball. Also noticed both the flow and return pipes are leaking under the boiler. Maybe time...
  4. T

    Intermediate Heat Exchanger

    All, really grateful for the fast feedback. We discussed a bypass valve but he thought "decoupling the boiler from the heating" would give a better and more consistent result. Although it's a bungalow, it is a pretty large 5 bed property, 2 bath and 3 reception. Sitting room/kitchen is...
  5. T

    Intermediate Heat Exchanger

    Approx 5 years old now. Everything was replaced including pipework. Motorised valves everywhere. Rads have Thermostatic valves as well. No bypass valve installed; it was discussed with the recent plumber but due to the size of the property and combination of heating requirements he felt a "low...
  6. T

    Intermediate Heat Exchanger

    Many thanks HB for you quick response. The system is fairly new and has always given us this problem. Yes, def not getting the water around and another pump may help but his main thought was is it a long way from one end of the house to the other.
  7. T

    Intermediate Heat Exchanger

    Folks, need some advice. I have a large, long "bungalow" with a Vaillant ecotech plus 630 at one end driving a closed/megaflow type system. It's a long way to the other end. We have mixed heating types: Traditional radiators, underfloor for the extension and polypipe overlay for the sitting...
  8. T

    Insulating a brick shed

    catlad, Sounds like a good idea.
  9. T

    Insulating a brick shed

    Lots of people store their freezers in un-insulated garages but they're not supposed to work very well below 10 degrees.
  10. T

    Insulating a brick shed

    Hi All, I have a 1.8M x 1.8M shed next to my house made from single skin brick. I'm moving the gas boiler in to it and want to put a freezer in it as well. Freezers don't like the cold so I'd like to insulate the interior walls with celotex. My question is, do I need to batten-out and...
  11. T

    LED Wiring Calcs

    Thanks for the top advice guys.
  12. T

    Bathroom UFH (yet again)

    Thinks we must be getting off-topic a tad but, as always, great feedback and timely advice plus a good bit of banter. ---- Okay, hands up, I'm not an eco-hippy. I work in London which is a 50 mile door-to-door trip taking 4 hours out of my life every day: I drive 12 miles to the...
  13. T

    Bathroom UFH (yet again)

  14. T

    LED Wiring Calcs

    Your "concern" is noted. It'll be in an ali conduit with clearish strip so it'll stay up there :)
  15. T

    LED Wiring Calcs

    Yep, using sticky tape stuff.
  16. T

    Bathroom UFH (yet again)

    Rather hoping it'll warm the floor tiles to stop my Mrs getting cold feet.
  17. T

    LED Wiring Calcs

    Thanks Simon, Great tip. I'll split the load and can probably get the run down below 2 metres. Cheers.
  18. T

    Bathroom UFH (yet again)

    Thanks for the very quick response. What I thought. Yep, my house has been gutted and is being re-fitted so lots of electrical work which needs signing of. Borough surveyor comes around on a regular basis.
  19. T

    Bathroom UFH (yet again)

    For the avoidance of doubt. I'm about to install electric UFH to my bathroom. I have direct access to the CU so can run a new spur. Most controller instructions say I need an RCD. Please confirm (or otherwise) that I can use the RCD in the CU and do not need to put another one near the...
  20. T

    LED Wiring Calcs

    I'm planning to install some RGBW +WW around the ceiling of a small bathroom room. Data is: Length 10M in total 24V 10W/M By my calcs that's 8.33A so I'll need a min of 10A rated cable. I'd like to use a single multicore flex such as YY 7 core 1.5mm to keep things neat and well within...