  1. S

    salamander pump - pulsing

    Have just replaced an 8 year old salamander RHP75 pump with a new one as the old one was making a horrbile noise. When i turn off the hot tap the pump continues to pulse (on/off) and the only way to stop it is turn the pump off and on again or turn the tap on again and off slowly. Appears...
  2. S

    SWA Cable in Garden

    Probably not good practice but is it against the regulations to clip SWA cable to a fence.
  3. S

    meter tails/Conduit

    Got a new install underway in a garage. Meter outside and CU inside with tails about 2 meters long and want to put these in conduit but 2 times 25mm plus 16mm earth bit big for 25mm PvC conduit. anything to say I can't use 32mm or 40mm domestic waste pipe.
  4. S

    Isolator

    I'm considering fitting a mains swith (one of these) www.tlc-direct.co.uk/Main_Index/Consumer_Units_Index/Contactum_Mains_Switch/index.html and www.screwfix.com/app/sfd/cat/pro.jsp;jsessionid=GDYVRDP0WONQMCSTHZPCFEY?id=74436&ts=83508 between the meter (new supply to garage) and CU. Due...
  5. S

    Meter Cabinet

    Having a new supply fitted to garage by EDF. I need to have a meter cabinet fitted to the outside wall. Have purchased the cabinet and hocky stick as specified by them. 2 questions 1. Is it upto EDF to seal the whole where the hocky stick enters the cabinet or uo to me/installer - hole in...
  6. S

    Garage Sockets

    Do you have to use metal clad sockets/switches in in garage or is it ok to use household white surface mounted boxes and sockets/swithes with cables in Pvc trucking.
  7. S

    intermediate switch

    anyone know where i can get an external intermediate switch from
  8. S

    Cable Size

    I want to run 3 300 watt spot lamps outside with 2 2way switches (1 will be 50 meters from the other so potentially 100 meter run for power from 1 switch back to the other). can i get away with 1.5mm 4 core armoured cable or will i need 2.5mm.
  9. S

    Garage - cable rating

    I want to run power from my shed to a garage. The shed is some 25 meters from the house and is connected via 2.5mm armoured cable connected to 2.5mm PVC cable (via internal junction box) which runs to house CU on a 16A MCB on the RCD side of the CU. The shed has a garage/shed CU with RCD...
  10. S

    Bella Cucina Kitchens

    Anyone had any experience of Bella Cucina Kitchens ???? Whats the quality and service like
  11. S

    Hob Installation

    Most Kitchen suppliers sell kitchen units to fit below Hobs. Is there any reason why I could not fit a 600mm hob unit in the work top above the join of a 300mm and 900mm corner unit. As the hob unit is deeper than the work top I would have to cut around 15mm into the top of the joining sides of...