    Baxi Back Boiler Firefront

    It is definitely 25/1 (GC4407751). Can you try and answer the other questions please. Also the Partsarena said that its compatible with GF Super, but does that include GF2 and GF3. Cheers!
  2. M

    Baxi Back Boiler Firefront

    Hi Guys, I have a Baxi Back boiler with an old C3W firefront. I thought the boiler was Baxi 552 because the manual i was given said it was. I wanted to change the firefront to a more modern one. So i bought a Baxi V2 from EBAY. When the fitter took off the old Firefront it showed that the...
  3. M

    Chimney Hood (Designair) changing to recirculation.

    i wnt to recirculate mainly because of the hassle o running the ducting and boring a hole in the wall and also whether i can hide the ducting.
  4. M

    Chimney Hood (Designair) changing to recirculation.

    Hi Guys, I am about to buy a Designair Hood ( either GCH60SS or FGHD62SS). The description state that they need to be vented (ducted). Is it possible to convert them to recirculation? These are cheap pieces of kit and i cannot find any website for the makers. i think they are sold in B&Q...
  5. M

    Baxi Bermuda 552 and 57/4M

    Thanks for the reply guys. How much would it cost for the parts i described earlier and is it ok to fit a used part from the same model. Roughly how much would a Corgi guy charge. cheers!!
  6. M

    Baxi Bermuda 552 and 57/4M

    Hi Guys, i currently have a Baxi Bermuda 552 Back boiler with a radiant fire front. The boiler needs changing because when i had it serviced it was noticed that the part where the flame is contained had some of the holes rusty and falling apart. I have been offered a 57/4M back boiler with a GF3...
  7. M

    Hole for downlights

    Cheers guys, i tried it on some hardboard and it works perfectly. Another question though. Does the 2mm gap affect the acoustic and fire rating of the fixture.
  8. M

    Hole for downlights

    Hi guys, I am fitting some 85mm downlights, but the holesaw i have is 89mm. The downlights have a lip of about 10mm. 1) Does the holes have to be exact 2) what difference will 4mm make cheers!!
  9. M

    Over revving ---- Slipping clutch?

    Hi Guys, I would appreciate some help on a problem i have. I have a m reg Laguna which is over revving. It is very slow uphill and petrol consumption has increased. It sounds like their is an exhaust leak. 1) How do you diagnose whether it is cltch slip 2) Is there any other...
  10. M

    downlight in acoustic plaster ceiling

    Hi Guys, I am just looking for some advice. I want to put downlights in a kitchen and a hallway but on inspection the ceiling appears to be of the acoustic type. It consist of a thin plaster sandwich with a yellowish foam substance in the middle. This is in a ground floor maisonette, so can only...
  11. M

    Fitting Spotlight

    Thanks for your replies guys.
  12. M

    Fitting Spotlight

    HI Guys, i would like to fit several individual downlights in a kitchen, but i have no access to the floorboard above. This ceiling is plasterboard. Can you suggest the various alternative ways of doing this. What about getting over joists? Cheers!!
  13. M

    Halogen spotlight

    Thanks for the replies guys. It does say that the unit is 240v. One more question please. You've stated that the unit is a low voltage one. There is no sign of a transformer. Are those built into individual lamps and should i just make the connection direct to the chocolate box. Can you also...
  14. M

    Halogen spotlight

    Hi i would appreciate some help to my query. I have a new Spotlight fitting with 3 lights. There is a 3 block chocolate connector which holds the cables. There is two small wires (black and white) going from each spotlight to the block. There is also an earth wire connected between the block...
  15. M

    Running cable from ceiling rose

    Thanks guys. I'll try that and i might get back to you for further help! Cheers!
  16. M

    Running cable from ceiling rose

    HI Guys, I live in a flat (apartment) and i am fitting a fan in the bathroom. I have no access to the lighting circuit apart from at the ceiling rose. Can i run a cable from the rose (burying it in the plaster. How would i do this? Cheers!