Hi
Anyone know a good way of cleaning the interceptor traps the u bends in sewer line with clay tea pot lid.
Mine is full of gravel that needs clearing.
I can't physically reach in and down so need to get debris out somehow .
Ideas ????
Thanks
Small cast iron rads to be fitted but existing pipework is 10mm fed from centre wall plate behind rad.
Any valves available to keep in line with the look of the rad? also need drainoffs as well.
Is this doable with speedfit pipe ?
Thanks
Hi
Tncs system
Log cabin 25m from house
See that when exporting earth 10mm earth is the prerequisite so would it be ok to use 4 core 6mm swa and double up 2 cores effectively making 12mm for earth.
And understand the need for non combustible in house ie metal consumer unit but how about...
Hi
Extension being built ground floor level.
King span insulation has been put down and floor will come up another 100m to finished level.
thinking of laying pipes in trunking on king span insulation .
What do people use for protection of pipes ie trunking and boxes to cover joints.
Where...
Can someone please help me understand the terminology involved when triggering outputs
Driving me batty
i have a alarm panel with negative remove outputs on trigger header
i have a gsm dialler with negative remove inputs or positive remove inputs
selectable via a jumper
can these be...
can somebody please help me make sense of trigger outputs
been on it for hours cant seem to get it to work
trying to add a smoke alarm to ademco galant alarm panel
have programmed z5 as fire zone & programmed trigger output as fire (on pcb board says trigger n/c)
all i want to do is...
hi
i have a galant alarm panel and want to add another texecom3 bellbox to my system.
Looking at panel spec it only has 500ma protection for bellboxes
I have another 12v 1a power supply i can fit in the box
but what are the connections to actual feed an additional bellbox from this...
Need to fit a door contact final entry/exit zone on an inward opening all glass front door in a small shop
Anybody know what best type of magnetic switch to fit or just standard one??? And best way to affix magnet to opening glass door so it doesnt come off in future.
Thanks
Need to add rad to house with a boilermate 2000 in .. Havent come across one of these before, any tips on draining refilling , or is there any way of adding rad without draining the system completely down , *&^@: big house,,,@:%$
cheers
i know its not the recommended route
but i already have this shower so if i connect it up will it work or am i wastin my time ?
thanks
i have a worcester 30 cdi combi
upstairs and downstairs lighing seperate circuits. See this situation most of the time with live feed at hall switch feeding both switches! and 2 core cable run up to landing switch therefore borrowing neutral of upstairs circuit.
What is the best way round this when fitting dual rcd board...