please note 9
Is the attached garage of a dwelling within the equipotential zone? The garage holds the boiler and associated pipework. Obviously the boiler will require a supply. But i was wondering if a 10mm earth is required out to the pipework?
thanks
Checking a house and found
1. Immersion wired in 1.5 mm and protected by a 15A rewireable.
2. Double socket spurred off a cooker switch in the kitchen.
Has anyone any solutions?
Does the immersion need rewired or a smaller fuse installed and is this likely to trip?
thanks as always.
Fault finding on a bell circuit... Three bells are installed on a circuit along with a push and a transformer. When 2 bells are connected the push will ring the connected bells. However when 3 bells are connected they will not ring. I think each bell is rated at 0.5 A. However the transformer is...
A chap has a garage which is being converted into an office. Standard set-up of boiler in garage and central heating controls in the house (timeclock).
At the boiler he has a 'house pump' and 'boiler' switch and also a separate 'garage pump' for the rad in the garage. The idea being to run the...
gents.
anyone any experience of installing a pump in a garden for a sceptic tank. What size is the pump likely to be and is RCD protection necesssary?
cheers
i am removing a counter in a shop. There are various compuetr points linked back to a main panel. I have never removed pc points before and was wondering if there are problems associated with doing so?
cheers
On the schedule of inspections, under (c) Protection against indirect contact - When is the 'Presence of residual current device' box ticked?
Also the 'Use of Class 11 equipment' - Does a double insulated emergency light fitting fall with this?
thanks
Gents,
What is required in a 'handover document' for a small commercial electrical installation?
The installation consists of the usual circuits. Also included is a fire alarm and emergency lighting.
I never heard of a handover doc before - only issued certs. - so any help is...
Isolator or switched-fuse?
Should there be an isolator of a switched fuse between the REC incomer and a cu? I have heard conflicting advice on this. In fact, it was suggested that nothing is needed in between. The run is approx 16 metres.
thanks
A portable building has a 3 way board controlled via 63a 100mma trip. This is fed via a messy three phase tns system. The protable building has lights, sockets & heater circuits.
The electrical components were installed and certified by the party supplying the building.
Surely the board...
Ive seen architects drawings that indicate a minimum clearance between the bottom of a bathroom door and the FFL.
I appreciate this will vary for different size bathrooms and their ventilation requirements, but is there a 'rule of thumb' or guidelines available?
thanks
Fitted a fan into a bathroom with a 'power shower', which produces a hell of a lot of steam.
The bathroom is approx 10 feet X 6 feet X 7 feet. The fan was a Manrose 4 inch inline fan with timer.
Some observations:
the fan does not adequately extract the steam.
there is an obvious...