  1. H

    Flame failure device

    Hi, I have asked this question in the heating section but not getting a decent answer. Does anybody know how to test a flame failure device on a central heating boiler.Thanks
  2. H

    Ariston microgenus 27 mffi

    Hi, Can anybody help, I run the heating or hot water the boiler ignites and after 5 second cuts out. The red light is then on after resetting the same problem happens.
  3. H

    Ideal Mini HE C24

    Hi, The boiler in my workshop worked fine for a while but now ignites and then cuts out after about 10/15 seconds. Also there is a spark on the control board which goes down the wire to the waste outlet. I have made sure that the outlet is not blocked, Please advise, Thanks in advance
  4. H

    Water Meter

    Hi again, Still trying to avoid large bills and lots of digging. (see my last post) Can I move my water meter to another site on my property or does it need to be done by the rip off water board. Thanks again.
  5. H

    New Mainswater supply

    Hi, Back again for more advice. Regarding my new supply, the water board will only run to my boundary, I have a sewer cover at one end of my drive and one at the other, can I, ugh, run a length of polypipe up this to remove the problem of digging my drive up. Thanks.
  6. H

    New Mainswater supply

    Hi, I am splitting my house into 2 units. A main building and separate granny flat. I have been quoted £1400+ to run a new supply from across the road to my boundary. I do not have a problem with the price if that is what the work is that is required My question is, Could the existing...
  7. H

    wiring colours

    Hi, Can anybody tell me when the present coloured cable (brown/Blue) was available for purchase by the trade. I did some wiring in the middle of 2004 but I am now being told that I could not have got the cable prior to Jan 2005. Has dementia finally got the better of me?
  8. H

    Kitchen electrics

    Hi, Is there a maximum number of sockets that can be fitted to a 2.5 ring? Do the cables have to be further protected if chased into plaster and tiled over? Can a dual fuel cooker be vented up an existing chimney? Any advise would be appreciated....Thanks
  9. H

    AristonDIA24

    Hi, Pressure guage fluctuates between 0bar and +3bar at times, boiler shuts down as if pressure low but comes back on. Pressure relief valve does not blow off when guage reading above 3bar. Help please
  10. H

    Ariston Dia 24 (update)

    Cannot find any reason for rads heating up on return line during hot water call, Would fitting a non-return valve to return line be an acceptable solution. Any advice would be appreciated, Thanks
  11. H

    Ariston DIA24

    When the hot water is being drawn the return on the central heating heats up, therfore heating radiators. Divertor valve has been replaced and all other inernal pipeworkand fittings checked for restrictions. Help please