  1. V

    Y plan system problem

    Sorted now! Tried removing the neutral but that wasn't it. A friend had an old programmer front same as mine, I switched it and now everything works fine!
  2. V

    Y plan system problem

    Thanks for your reply, An electrician told me I should remove the neutral from the new honeywell thermostat, as it is no longer needed. I will try that when I have time, unless anyone knows a reason I should not...
  3. V

    Y plan system problem

    My honeywell mid position zone valve has five wires as follows. Blue (connects to neutral in wiring centre) G/Yellow (the earth) White (connects to one of the black room stat wires, terminal 3) Grey (connects to cylinder stat in wiring centre along with another wire which should...
  4. V

    Y plan system problem

    Its fully pumped, with one, three position zone valve.
  5. V

    Y plan system problem

    I ripped down the kitchen ceiling to get to the pump, bled it, and wahey! Heating works now. Just need to get to the bottom of the room stat always making boiler fire up problem now. Seems like a wiring problem to me, my honeywell stat is wired as follows; T6360B Terminal one = red...
  6. V

    Y plan system problem

    I tried all manner of airlock removal tricks yesterday for 5 hours but still have same problem. Some silly bugger has concealed the pump above the kitchen making it totally inaccessable, the kitchen is an offshot and is also where boiler is, I will expose tonight and try venting/hitting with...
  7. V

    Y plan system problem

    I've just moved house, been in less than a month, since moving a radiator i've been having severe problems with my system. After refilling and removing air, I found only the upstairs rads get hot, then suddenly the boiler wouldn't fire at all when CH was programmed to be on (hot water worked...
  8. V

    Cost of gas central heating.

    I've tried to calculate whether it's as cheap to run gas central heating with all the radiators on or to turn radiators off in unused rooms. The heating has been on for exactly the same times in the day. In the quarter of November, December and January 2005-6, I ran the central heating with all...
  9. V

    new saniflo macerator not pumping high enough

    The entire run is in 22mm copper, the horizontal run is around 8 metres which should be fine as 10 metres is allowed when using a 5 metre vertical lift. What is most annoying is not being able to rule out the 5 metre vertical run issue, after allowing 50 cm for each bend on the lift it works...
  10. V

    new saniflo macerator not pumping high enough

    I have just fitted a saniplus for a bath, basin & W.C. The thing pumps constantly when full and doesn't get anywhere. The instructions say it can pump 5 meters vertically, my vertical pipework is just slightly more than 5 meters including allowing for 45s & bends but surely cant be the...
  11. V

    wet room

    Thanks Moz that website you recommended is very good.
  12. V

    wet room

    It's OK thanks I know what to do now, I contacted a firm that installs wet rooms.
  13. V

    wet room

    I am tiling the floor of my wet room with large tiles. What could I use for the bit that needs to slope to the drain in the middle of the floor please?
  14. V

    water aeration

    Do you know how the water is aerated when using taps. I liked this effect when I used the toilets in a shopping centre.
  15. V

    mixer kitchen sink taps

    Hello bab, no I didn't buy the cartridges, perhaps that's why they don't work properly. Thanks.
  16. V

    mixer kitchen sink taps

    I replaced the knobs on my hot and cold mixer taps with lever type heads, but they don't work properly because they spin round instead of quarter turning. Is there anything I can buy to put on the original taps to rectify this or will I have to buy the whole taps unit?
  17. V

    overheating combi boiler

    We've a 2 and a half years old Potterton Performa 24 combi boiler. We've had no trouble with it until yesterday, when, even on a low temperature rating it was overheating the radiators. The dial had no effect on turning the heating down. Help please? :roll: