  1. D

    Lockshield and TRVs

    Additional question Should the pipework be adjusted as per this diagram With the yellow being the return (moving the T-Junction away from the radiator) and the same with the green being the flow? That way, in my mind at least, they are not "fighting" each other for flow or return?
  2. D

    Lockshield and TRVs

    Ok, I have lifted the floor, before flushing or doing anything in the system. In the picture attached you can see the radiator in the room (top left, with the TRV on the flow side marked in red). This flow comes from "somewhere" else in the house. However, when the system is on, the pipe...
  3. D

    Lockshield and TRVs

    System is a combi boiler which is pressurised. I have the ability to refill the system if the pressure is low. I will take the radiator off, connecting to a hose to the drain, keeping the pressure built up. I can't do this till either Wednesday or next week, Terryplumb, however I will...
  4. D

    Lockshield and TRVs

    Yup sure does
  5. D

    Lockshield and TRVs

    That's kinda what I thought too. Yup, I will remove the radiator. I am thinking, removing it, check for sludge (maybe an obvious one), then on the lockshield side, open it open to see if any sludge or blockage on that side. If that is clear then I can only assume its plumbed in wrong. Any...
  6. D

    Lockshield and TRVs

    Morning, Thank you for the suggestion. I have tried the test. IE. closed all TRVs off, except the radiator that doesn't heat up. The radiator flow pipe gets "warm" and there is some minor heat in the radiator. When I say heat, slight warmth. I am suspecting 1 of 2 things. Either the...
  7. D

    Lockshield and TRVs

    Thanks ill give this a try in the morning. Assuming it does heat up, any thoughts?
  8. D

    Lockshield and TRVs

    Hi all, You have been incredibly helpful in the past and therefore I am hoping you can help me again! I have a radiator problem. Since moving in, the radiator upstaris in the spare bedroom has never been able to get hot. This was installed by the previous owner. All other radiators in the...
  9. D

    Monarch PS11 Water Softener

    As you can see, it doesn't have a timer on top, its the previous version. I suspect that no power is going to the regenerator, hence no recycling in the evening. Any idea where I can start to diagnose this. With reference to the 6 months, this unit was one that my mum and dad didn't want...
  10. Untitled

    Untitled

  11. Untitled

    Untitled

  12. Untitled

    Untitled

  13. Water Softener

    Water Softener

  14. D

    Monarch PS11 Water Softener

    All, I always come back to this forum for help and have found you guys extremely useful in the past. About 6 months ago I had a water softener installed outside my kitchen, which I have since boxed and insulated. In the last week I have noticed that we do not have soft water in the...
  15. D

    Doors and Windows help please

    Crank, Thanks! You were 100% spot on. All vents are in, and door adjusted. Thanks a million. Doobs.
  16. D

    Doors and Windows help please

    Guys, Installed new conservatory over the last few months. I need help on two things please. First one, the windows have spaces for vents, I have the plastic vents, but have no real idea of how to fit them please. Can you guide me on what vent goes on what side of the window...
  17. Untitled

    Untitled

  18. Untitled

    Untitled

  19. Untitled

    Untitled

  20. Untitled

    Untitled

Back
Top