    Indesit washing machine fault code f-03 suggests that the...

    Thanks for the reply. I thought as much. Have you ever repaired them? I'm going to take this one's apart, been told that it can sometimes be a faulty resistor!
  2. B

    Indesit washing machine fault code f-03 suggests that the...

    Please provide me with some help on this one... On my Indesit WIE167UK have fault code f-03, I found that this means the element sensor / thermistor is faulty(NTC). I tested existing NTC and at room temp had 15Kohm, under cold water open circuit, hot water (40'c) 5Kohm ( same as a brand new...
  3. B

    rigid shower fitting...

    the shower is fitted with a mixer tap and the water feeds are from mains and combi boiler. turning shower full on, the water runs cold til hot water runs (obviously), this is ok then after a few seconds at this very hot temp, the hot pipe knocks. Turning the mixer tap for colder water stops...
  4. B

    biasi combi boiler m90f.28s slowly losing CH pressure...?

    Also used as an anesthetic, something Vaillant engineers need to work on their kit. I didn't sayit! :mrgreen: LOL "One house I bought was owned by a DIY nutter. That's nutter in capitals and neon lights. I think B&Q must have had his picture up with candles in front of it. If he could get...
  5. B

    4m x 3m poly tunnel

    might try 40mm waste have loads left from a kids goal making project (screwfix again). If i push some 12mm steels in the ground then bend the pipes between these it could work. Yes, must be careful of the winds tho.
  6. B

    biasi combi boiler m90f.28s slowly losing CH pressure...?

    Well thanks for all your helps, its appreciated. I not changing the settings as we're getting better results than before, offdownt'pub to see if there's any rubbish wit face on't bar. Cheers
  7. B

    biasi combi boiler m90f.28s slowly losing CH pressure...?

    Just back from over the pond and it's better than ever, released a bit of pressure and now max is steady at approx 2bar. Better half reckons that DHW is better controlled. Regarding the mains water, I don't have much in my system. Its microbore etc , my own design after I did all those U...
  8. B

    4m x 3m poly tunnel

    I was thinking about some sort of plastic piping like for water or waste? Woods ok, but I'm looking for a curve.
  9. B

    biasi combi boiler m90f.28s slowly losing CH pressure...?

    I turned off the unit last night and this morning checked the EXV pressure. It was virtually nil, and had a bit of damp hit my hand, reckon this is condensation. So I set about repressuirsing the EXV. Turned off the flow/ret cocks and opened the drain next to the pump. At first nothing much...
  10. B

    4m x 3m poly tunnel

    Hi everybody, Anybody know how to make a 4m x 3m poly tunnel? I would buy one, but like making stuff and they are expensive.
  11. B

    biasi combi boiler m90f.28s slowly losing CH pressure...?

    Hi Agile, Thanks for that, it appears to be working properly at the moment except for pushing out about 1/2 pint of fluid from the safety discharge pipe. It drops about 0.4bar so I've been refilling regularly. But, I've just noticed that it is running hi pressure, when hot, between 3 and 4bar...
  12. B

    biasi combi boiler m90f.28s slowly losing CH pressure...?

    Hi all, I have a Biasi combi boiler m90f.28s, its slowly losing CH pressure in the last few weeks. The loss in CH water is about 0.4bar per day. The external system is ok, can't find any leaks. At first, thought it was the heat exchanger because when it had its service back in November...