  1. B

    draining central heating system

    cheers. what do i with regards to the boiler, ie switching off, leaving it, resetting it? and re filling it. dont want to balls up the sensor again
  2. B

    draining central heating system

    hi all, i need to install a new radiator to a room without an existing one so i need to drain the system. i have a vailant ecotec pro boiler fitted. i did drain the system a couple of years back to move a radiator but i then had to have the water sensor replaced, not sure if i did...
  3. B

    Stained Glass Triple Glazed Window

    i would do it the way they've said, it will look fine
  4. B

    double glazing a hardwood door

    no not at all
  5. B

    double glazing a hardwood door

    what is the max thickness between the frame and beads (strips) you will need at least 14mm
  6. B

    double glazing a hardwood door

    depends if there is enough room for one
  7. B

    Crown glass v horticultural glass

    we sell restoration glass for what you are looking for but it is quite expensive
  8. B

    Double Glazed Window jammed in corner - Please advise

    take the unit out first then try to open it.
  9. B

    Changing frosted glass in an engineered door

    most front doors come with a complete panel and you cant change the glass you have to change the whole panel. you can get doors with clear glass for no extra cost ,depending on what you want, may sound silly but try looking at back doors you may find what you want
  10. B

    vaillant boiler query

    yeah he pumped it up but its leaking. said it would probably last the summer but not when the heating strats being used constantly. going to get the external one fitted when i can
  11. B

    vaillant boiler query

    someone came today and fitted a new sensor. its working for now but needs a new vessel. he said my best option was for an external one? got to ring him later and speak to him about it
  12. B

    vaillant boiler query

    there is power going to the board and pump but the boiler is dead, no lights or fault codes. this happened after a drop in pressure due to a leak on the pressure sensor . pressure is back up but boiler is dead. all fuses ok.
  13. B

    vaillant boiler query

    there is power to the board, not sure about the pump. how can i check?
  14. B

    vaillant boiler query

    hi, i have a vaillant ecotec pro and it looks like i need a new pcb. just a couple of things i need to know. how can i tell which model it is so i order the correct pcb, and are they difficult to change? and how much should i look to be paying for one? had no heat or hot water for nearly 3...
  15. B

    UPVC Patio door hinge replacement

    yes remove the glass and go with flag i would. easier to do on your own
  16. B

    Double glazing misting problem - but not all the time.....

    lady lola:- it was tongue in cheek. when manufacturing dgu's the whole process is done by machine hardly any man involvement, thats the very big firms anyway. the small local firms all do it pretty much the same way as each other where 1 or 2 men cut the glass by hand cut the spacer bar by...
  17. B

    Double glazing misting problem - but not all the time.....

    hi, what you are doing is all very new to me but could be worth a go. the problem i see is with the dessicant. i always throw away dessicant that has been exposed to the atomsphere for more than 8 hours because i deem it useless as it causes dgu's to steam up when sealed (especially in winter)...
  18. B

    UPVC door with mostly knackered locking mechanism

    the door is probably fine. your lock is knackered. firstly does the key turn at all
  19. B

    Double glazing misting problem - but not all the time.....

    yes you can do this to leaded units thats what i meant by decrotive dgu's and these are the most likely that need repairing. you just have to be carefull not to damage the lead when doing so. the most common sealeant is, what they call in the trade, hotmelt. this comes in a number of...
  20. B

    Double glazing misting problem - but not all the time.....

    if you want to repair a broken down or "misted" dgu the best way is this. 1/ carefully split apart the two panes of glass with a stanley knife. slicing where the glass meets the spacer bar. (be very carefull and take your time. you will need to slice each edge a number of times) 2/...