    Increasing cold water storage in loft

    Hi all Intending to fit a pump assisted Mixer shower valve, upon reading the MIs I see that my cold water tank in the loft needs to be at least 50 gallons capacity, Upon inspection I only have a 25 Gallon :cry: I have limited space thanks to modern day trusses! And cannot get a 50 gall in...
  2. O

    need to change programmer

    hi all Got a basic ch/hw vented and pumped system not a combi. with a 3 port motorised valve. Need to change an old randall 3020p mk3 dial type programmer, are there any out there that assist in the change over, ie existing wiring, what goes where etc to the new programmer?. Is it ok to go...
  3. O

    overheating shower isolating switch

    Just read the majority of posts and replies regarding overheating shower switches. I,ve got a triton bewitch 10.5kw unit, supplied by 10mm T&E over a run of 10mtrs clipped to joists avoiding any insulation material. At the CU it is protected by a 50amp mcb on rcd side. The supply terminated...
  4. O

    RCD didnt trip!

    Hi all Please help, got a nice new split load rcd protected cu. Over the weekend my wife was using the dreaded hedge trimmers and cut through the cable, bit of a spark but she was ok, my main concern is that the rcd side of the board didnt cut the juice! all the sockets are on the protected...
  5. O

    insulating a solid wall

    hi all, can anyone help, Had a two storey extension shell built (over garage), the main side wall to the extension has come straight up off the garage wall which is 4" block with facing brick (no cavity). In order to comply with reqs plans show the following spec, Breather membrane to...
  6. O

    6mm shower cable

    yeah I know, sorry lads this one again! Used the search (as long as I could anyway) re shower cable. CU s about to be changed along with other configurations, relating to new house extension, having read all previous posts regarding shower cable was eventually able to convince the old fella...
  7. O

    rcd in cu

    Gota nice new shiney split load Cu 6 +6, the rcd is a 63A 30mA, i have the option of changing this to 100A 30mA (got a spare compatable) would this option increase my diversity? or cause me probs! On the rcd side i would have the following 1x 50amp = shower currently 7.5 (upgrading...
  8. O

    Plinth Heater power supply

    Iv,e bought 2 x 3kw plinth heaters for the kitchen, initially I was going to feed these by way of plugging them into socket outlets which allready exist just in the right places behind the kitchen units, (both sockets are on the same ring), However considering the potential draw if both were on...
  9. O

    central heating pump on constant

    hi all Recently changed a friends central heating pump for a more powerfull one, which solved the initial problem of radiators in his new (large) conservatory not getting warm, his room stat was also a bit dodgy, falling foul of being badly located on the stairs! so replaced that with an...
  10. O

    access to lv transformers and connections

    had a two storey extension (shell) built, doing internal myself! completed kitchen area and installed 15 lv recessed spots, in ceiling each on individual transformers and looped. On 2nd storey now and about to fit floor above kitchen (8x2 chip) t&g. on top of this is goig to be an en-siute...