  1. C

    Help with Alarm PIR Wiring

    Hi everyone, would like a bit of advice regarding the wiring and replacing of an old PIR. This PIR is in series with another one for the Zone From the picture, my assumption is:- A = + (Two wires as got to other pir) B = - (Two wires as got to other pir) C = just joined (NC to other PIR) D &...
  2. C

    How to fix new Chipboard on top of existing Chipboard

    Hi, After a new extension we now have a lounge floor 18mm lower than the kitchen extension so i'd like to re-floor the lounge with new Chipboard on top of the existing Chipboard to make it level. Question is, which is the preferred method of securing the boards, would it be screws, wood-glue...
  3. C

    New Boiler - Long flue or pump ?

    Hi everyone, I'm having a new Vaillant ecotec 430 fitted next week, fitters have offered two install places ( both in the garage) 1) Outside garage wall = short 1m vertical flue + condensate pump + extended flow/gas pipes +£52 2) Inside garage wall = 1m vertical then 4m horizontal flue but...
  4. C

    Heating on as per timer but pump shuts off after an hour ??

    Hi guys, if somebody could offer any advice on my issue it'd be really appreciated. I've an old 'Glow-worm Fuelsaver' balanced flue boiler, with Drayton timer & stat. The timer correctly switches the heating on and radiators come on but only for around an hour then the pump goes off whilst...
  5. C

    Break in 22mm Heating Pipe.... How best to mend ?

    Morning, I have a slight problem which i'm hoping that you guys can offer some advice... I accidently cut a 3mm nick in a 22mm central heating pipe (non combi) under the floorboards of a bathroom. Whats the best way to repair the problem because the nick is on the side of the pipe next...
  6. C

    Flexible Conduit & Adding A Switch To Low Voltage Lighti

    Can anyone shed a bit of light (excuse the pun) on these couple of questions. Can ribbed, flexible conduit (screwfix sell a 10m kit) be used outdoors, i need a 2ft piece up the outside of a wall which is permanantly 'out of the sun'. I thought it might be a better way of feeding my wire...
  7. C

    External Mains Supply For Garden Lighting

    Hi, Can anyone point me in the right direction as to whether the following will work ? I want to power:- 6x 240v 11w lights 1x 20w transformer (for a set of 'step' led's) 1x v small pond pump (450L/Hr) These will be powered from an RCD on a 13amp socket indoors My Plan:- I've seen...
  8. C

    Alarm System - 4 Wire Bellbox ???????

    Can anyone give me abit of advice, i've just replaced an old Omnicron 8000 control panel with a new Veritas panel. The bellbox was wired to the old panel by only 4 wires....see below Bellbox Omnicron 8000 New Veritas 8 H+ --------- Bell+ ----------- A S ----------- Bell- ------------ B...
Back