Search results

  1. iamSteve

    Honeywell Flex 20 - Network and Pulsing Siren

    Just to close off this thread, thanks GalaxyGuy for the tips and advice regarding my system both in the thread and by PM/Chat. I have replaced A083-00-01 with the newer A083-00-02 following GalaxyGuy advice and hope that the fault no longer appears and the Ethernet card stays connected to the...
  2. iamSteve

    Honeywell Flex 20 - Network and Pulsing Siren

    Not installed that long ago, I purchased and installed at the start of 2017. My Optima XM panel on my house is old at over 20 years. I will send you a PM about connection.
  3. iamSteve

    Honeywell Flex 20 - Network and Pulsing Siren

    So the information I have is FX20 V3.18 Ethernet 100% CM04 V1.02 From what you have said my internet failing and me getting the remote login wrong several times locking myself out of the panel for a time are both massive coincidences with the alarm trigger and later in the evening the...
  4. iamSteve

    Honeywell Flex 20 - Network and Pulsing Siren

    Just to add the the above, I have just checked Ethernet line fail [56.3.3.6] and it is (and was) Disabled. When exiting Eng mode, it now says modules was 7 now 7, late last night it said was 6 now 6??? I have not re enabled anything today.
  5. iamSteve

    Honeywell Flex 20 - Network and Pulsing Siren

    Hi, Hopefully someone can help with this issue I had yesterday.... It started when my home router lost power, sometime later my studio (a separately alarmed building) started alarming. My wife went to reset it and told me it said something about Com 4. When I got home from work I had a look at...
  6. iamSteve

    New Alarm Help... Please

    Just to clarify, when I said it does not need many zones.... I am not bothered if it has the facility for 12+ zones, I don't have to use them! Just trying to provide as many facts as possible. For PIR's the Bosch Blue Line Gen 2 BLD2 TriTech Blueline Detector sound good? Any comments...
  7. iamSteve

    New Alarm Help... Please

    I am installing an alarm in my garden office, it does not need many zones but I want to be able to install customise it myself. My wish list.... Separate keypad (without front flap would be nice) PIR's that I can rely on no false alarms Phone dialler / text to inform me of alarm status...
  8. iamSteve

    Timber Garden Office - Wall noggins or not?

    Yes they are 600 centers for the wall 100x50 and the 225x50 roof joists.
  9. iamSteve

    Timber Garden Office - Wall noggins or not?

    All the play are 8x4 sheets. I appreciate your comments and suggestions, however I am trying to keep the room with every inch of space I can. I made the walls out of 50x100 timber C16/C24 to ensure I have a depth for the insulation and also strength to support the roof. All timer and ply...
  10. iamSteve

    Timber Garden Office - Wall noggins or not?

    I am building a garden office, timber construction, insulated with plasterboard walls finish. You can see from the photo below I stared fitting noggins in the walls corners and around the doorway, I then halted this to get the roof on asap due to the weather. I have the timber here to fit...
  11. iamSteve

    Roof timber

    I am unable to help with your questions, however recently I was looking for the difference between OSB 2 and 3 and found this information... Four grades of OSB are defined in EN 300 in terms of their mechanical performance and relative resistance to moisture. These are: OSB/1 - General...
  12. iamSteve

    Re: Timber garden office vapour barrier

    Just to assist with my explanation regarding roof ventilation above. Front Joist over hang, I assume I will need to trim out the membrane to allow free air flow under roof deck, was thinking of fixing batons along the front and using the cladding offcuts (opposite way to the wall)...
  13. Roof Rear

    Roof Rear

  14. Roof Front

    Roof Front

    Front overhang, for ventilation and LED lighting
  15. iamSteve

    Re: Timber garden office vapour barrier

    Mid span is roughly where the PB will join anyway.
  16. iamSteve

    Re: Timber garden office vapour barrier

    Thanks once again. Yes my roof is a cold deck design and will have a 50mm air gap at one end and 150mm air gap at the other end, so a minimum of 50mm gap between the ply and the insulation anywhere on the roof. The joists overhang the outer ply wall by 100mm at the rear (bottom of the...
  17. iamSteve

    Re: Timber garden office vapour barrier

    Same subject but different area of the office.... I have the joists and furrings in place with 18mm ply as the roof deck, once complete I plan to cover the deck with Firestone EPDM Heavy Duty 1.52mm Membrane stuck directly to the ply. Like the walls I intend to use foil backed plasterboard...
  18. iamSteve

    Re: Timber garden office vapour barrier

    Thank you for your assistance alastairreid This is the garden office wall construction thanks to your assistance. Just in case anyone wonders why the battens stop short of the top of the wall, it is because some work needs to be undertaken to finish the roof section before the cladding...
  19. Front Office Wall

    Front Office Wall

  20. Internal Roof Structure

    Internal Roof Structure

Back