    Zone valve wiring into existing CH system

    As it happens I have two two port valves so an s plan would work for me but I am unsure as the best way to wire it. Currently there is a combi boiler and manual room stat. Now I have fitted a ufh manifold, it has voltage free contacts. Can you knock me up a simple diagram on how you would...
  2. F

    Zone valve wiring into existing CH system

    If the room stat calls for heat the zone valve would open, the rads have no trvs so there will be no issues. I think u are thinking the ufh thermostatic valve is like one on a radiator? It isn't it is incorporated in the ufh manifold, it has no influence on the radiators. Steve
  3. F

    Zone valve wiring into existing CH system

    The CH stat has two poles so I can emulate a hot water stat. I thought three port valve return to HW off without power? Anyway, I do actualy have two two port valves but have never done an s plan. Do I need a bypass in the system though with s plan? Originally I had in mind a simple...
  4. F

    Zone valve wiring into existing CH system

    There is no hot water cyclinder, so surely a y plan set up as if the ch stat was the HW stat and the ufh call set up as if it were the CH stat would do the job? Steve
  5. F

    Zone valve wiring into existing CH system

    Actually the answer was obvious, I need to go standard y plan with a three port valve! don't worry Bernard , I'm not planing to heat the floor to 70c;-) Cheers chaps Steve
  6. F

    Zone valve wiring into existing CH system

    Hi chaps, I am building an extension for the outlaws it will have underfloor heating. I want to link it to the existing CH system by linking into the main feeds and fitting a zone valve to the CH supply so the rads don't heat up when the ufh is calling for heat. The ufh will call for heat and...
  7. F

    Supply only plastic windows?

    Can a anyone recommend a supply only UPC plastic window and door suplyer online or in the midlands please that do sculptured modern looking profiles? Ta ducks, Steve
  8. F

    Profile identification- Carrington Windows of Derby

    I wouldn't have thought themed be choping and changing from profile to another will they? I thought the had different tooling for each profile? Looking at duraflex, I'm not sure the sealing bead is the same, the ones on these windows look more like synseal synergy. It is defo a...
  9. F

    Profile identification- Carrington Windows of Derby

    Carrington Windows of Derby...anyone know what profiles they use? Building an extension for the outlaws, the rest of the house has had recent(last few months) new windows fitted at some great expense, I want to fit the same windows so as to match. Cheers Steve
  10. F

    Concrete roof tiles

    Thanks chap, yeah, can't see why they have to be painted...the concrete surface now exposed is smooth so moss can't get as good a grip and water is unlikely to get into cracks and cause spalling. Just hope the outlaws like the look...... Steve
  11. F

    Concrete roof tiles

    I am building an extension for the outlaws and decided to jet wash the roof tiles on the existing building to rid it of moss and restore its original colour.... However! I ended up removing the sandy surface too and exposing the bare concrete of the tile. I think it looks fine, but the...
  12. F

    Flat roof insulation..thermally broken fixings?

    PU? Soz chap but what are they? Ta Steve
  13. F

    Flat roof insulation..thermally broken fixings?

    Celotex's app gives thermally broken fixings as an option to fix the insulation to the deck, but the BM doesn't know of any available and googling hasn't bought anything to light...has any one used them? Ta duck Steve
  14. F

    New flat roof- joist hangers direct to walls?

    Simpson strong tie sae 250/76 Have decided to hang them on the one side as originally suggested, but use the above straight on to block. Shed wasn't much use really! Building inspector happy to go with what ever manufacture said. Steve
  15. F

    New flat roof- joist hangers direct to walls?

    Hi all, building an extension for the outlaws, never done a flat roof before. Architect had one side of the lists hung off joist hangers and the other side let in to the double leaf outer wall. I was wondering if I could joist hangers both sides, so after a convo with the shed, and a convo...
Back
Top