  1. J

    Plume kit

    Hi there I’m looking at having my boiler relocated, having looked at the regulations regarding distances from walls, windows etc can find no info on the maximum number of 90 degree bends you can have. Ideally I’d like the flue to exit the boiler to the side then a 90 degree bend through an...
  2. J

    Garage power

    2.5mm is to his spec Its 600mm deep to his spec im adding the warning tape to his spec The feed is direct from the CU to his spec He never specified any conduit its more me beng curious really Thanks for the replies chaps
  3. J

    Garage power

    As part of a total house renovation im adding power to the garage using 2.5mm swa buried underground. Its all getting signed off by a qualified electrican i just want it right before he arrives. My question is where the cable exits the house, there will be approx. 6" of vertical cable on show...
  4. J

    87.5 Degree rest bend

    Thanks guys makes sense now, why cant they all stick to one format eh?
  5. J

    87.5 Degree rest bend

    Can anyone tell me why rest bends are sold with an angle if 87.5 degrees, im puzzled as surely they need to be 92.5 or it mucks up the fall? Tvanks JB
  6. J

    Bath waste query

    Thanks for the reply squeaky much appreciated
  7. J

    Bath waste query

    My reason for asking is that the bend fittings are all either 135 or 90 degree angles. Why arent there any 137 or 92 degree ones to take the drop in to account? Do you have to rely on the pipe bending? John
  8. J

    Stainless flexi hose

    Perfect just what im looking for Cheers John
  9. J

    Stainless flexi hose

    What would you guys recommend for a cold water shut off tap on the feeds in the bathroom, as again the ones ive seen restrict the flow big time? John
  10. J

    Stainless flexi hose

    Its fed from a combi so might give it a try, failing that the plastic pipe idea sounds like a plan! Thanks for the replies John
  11. J

    Stainless flexi hose

    Im looking at fitting stainless flexi hoses to a new bath im installing but have noticed the internal diameter is half the 15mm of the copper pipe. In reality does this affect the flow as much as it looks like it will? John
  12. J

    Bath waste query

    On 40mm bath waste pipe does the drop have to be constant along its length or, can you have horizontal, 45 degree drop, horizontal? Id like to have the pipe come out of the S bend horizontal for 300mm then drop at 45 degrees to go under the floor, then back to horizontal for 2m and out...
  13. J

    Solvent weld

    i'm completely refitting a bathroom, ive 'heard' that on new installs that push fit cannot be used, solvent weld only. Is this correct?
  14. J

    Cable clipping

    What are the regulations on a rewire with regard to clipping cables to joists? Ive heard/read that 2.5 needs supporting every couple of feet or so, but without lifting a heap of floorboards hows it done? Is it acceptable to have them just resting on the floor/ceiling? Regards JB
  15. J

    Fitting a drain valve

    Thanks Armo they look neat! Is it ok not quite being at the lowest point on the system or are am i being too picky?
  16. J

    Fitting a drain valve

    Im in the process of installing a full central heating system to an old terrace property, when it comes to the drain valve, im assuming its best fitted on the lowest point, but is it better on the flow or return side? Regards John
  17. J

    Pipe run query

    Im installing a new CH system from scratch, the query I have is regarding the routing of copper pipe. After going through a notch on a joist the pipes have to then run 'with the joists' for some 4m. My question is, do the pipes stay side by side horizontally with noggins between the joists for...
  18. J

    Vapour confusion

    Marvellous thank you for that :)
  19. J

    Vapour confusion

    Im renovating a mid terrace house and am drywalling the exterior walls using 50mm polystyrene and studs. Ive spent a very very confusing weekend trying to decide on where to fit (or IF to fit) a vapour barrier. Some say vapour barrier against the brick the the studs, others say ooo no bad idea...
  20. J

    Floor levelling

    The difference in the current concrete floor is up to 50mm difference, just figured it'd make getting the frame nice and level easier then masses of different sized shims - or is there another way?