  1. P

    Is it possible to overide wall control unit for Worcester Bosch Boiler

    Is the reciever built into the boiler or do you gave an external one?
  2. P

    TRV issue, now discovered broken pipes in concrete floor

    Not what you want on a Saturday evening :cry:
  3. P

    TRV issue, now discovered broken pipes in concrete floor

    Usually you can tap the the lockshield when on the tail piece to slide the olive further into the tail piece it can be tight though
  4. P

    Grass yellow and dry

    This is what it looked like after first couple of cuts and was mowed at highest setting
  5. P

    Grass yellow and dry

    Can anybody steer me in the right direction I laid turf in may and it has been beautiful until noticeably the last 2 cuts. The ground is heavy clay but was forked and rotavated then left for a year after moving in then 3 ton of topsoil was put down raked and walked in before turf laid. The...
  6. P

    Supporting sleepers

    I have almost completed my sleepers project although my wall isnt as tall as yours. I did however change my plan a little and went for 16mm rebar through the bottom sleeper set in concrete and then 300mm timberlock screws on the second row I did take the advice and put some 20mm gravel behind...
  7. P

    Cordless drill recommendations

    Makita 10.8v suitable for most jobs and if you look about you can get the drill and impact driver within your budget I have them aswell as an 18v Bosch drill and impact driver and often find that I don't use the 18v unless I have a lot of work to do and battery life is important
  8. P

    Central Heating System replacement advice

    Yes I've used these before with no issues Insert in the 15mm plastic pipe push your fitting home and the other end into the bottom of the trv with nut and olive connection
  9. P

    Central Heating System replacement advice

    If it makes you feel any better about it they are a b******d to get apart without the tool they have a locking ring type fit I've yet to see someone pull one out
  10. P

    Central Heating System replacement advice

    What your suggesting will work Any reason behind not wanting to use the push fit method as it will certainly look a lot better than what your suggesting?
  11. P

    Central Heating System replacement advice

    Looking at the swivel fitting your thinking of using looks like it uses a washer sealing method but the trv will be a compression type with an olive You may be better of with something like this...
  12. P

    Central Heating System replacement advice

    http://www.plumbingproducts.ie/chro...chrome-327-compression-swivel-elbow-15mm.html Are you using these to go from the plastic to the trv?
  13. P

    Supporting sleepers

    Hi Looking for some help with supporting sleepers I've split the garden into 2 levels and am using sleepers narrowest side on the ground stacked 2 high they are around 2 metres long either side of the stairs. Its holding back 400mm of soil my plan is to use concrete Spurs to hold them in...
  14. P

    Hive 2 receiver location

    Frost protection is off the hive thermostat and it will be fine to install reciever in place of programmer Paul
  15. P

    Hive replacing Horstmann installation advice please

    I thought hive came with bg installation?
  16. P

    Air bricks new build home

    For those that have helped into now just thought I would update you on what's happened so far So last week I found out the site manager no longer works for persimmon so basically went right back to the start. But after a few angry conversations with the after care team they sent an inspector...
  17. P

    Air bricks new build home

    I can only asume that it's there based on what site manager has said he told me they put 2 levels of damp proof in would that sound right? It is definitely visible at the front of my house but I know what you mean normally it quite obvious but not in my case