Search results

  1. B

    potterton suprima

    No didn't run it dry as the fused spur for the boiler was also on the same wall which is now gone and relocated the spur. Bleeding all the rads took ages through, stupid 10mm pipe work. Mother only moved in 2 weeks ago and since then 3 rads weren't getting hot. After lots of bleeding all the...
  2. B

    potterton suprima

    I'm working in my mother inlaws house fitting a kitchen. Had to drain down to move a radiator in a wall being removed. Did all the plumbing required and refilled system and bleed all rads and bleed valve by cylinder. Now the boiler comes on for anything from 5 minutes to 45 minutes before...
  3. B

    gloss for woodwork

    Any idea how much would be needed to do 15 doors and other woodwork in a medium size 4 bedroom house?
  4. B

    gloss for woodwork

    Are all water based glosses comparable then?
  5. B

    gloss for woodwork

    Any suggestions for a gloss white for interior woodwork, it has to be the lowest odour possible as my wife has allergies and asthma against paint fumes.
  6. B

    best current paint offer?

    Cheers for the advice, no danger of going anywhere near the shed own brand watery faded rubbish. Already have some water based gloss left over from some customers jobs so that one thing sorted.
  7. B

    best current paint offer?

    Where is the best place to buy good quality paint from as I'm now ready to decorate our whole 4 bedroom house after extending it so need a few pots of the stuff. All ceilings white emulsion All walls various colour emulsion All wood work gloss white has to be lowest odour possible due...
  8. B

    Iron svp

    If i cut the existing svp down to a height 300 above flood level Is there a special fitting required to join the iron svp to an aav?
  9. B

    Iron svp

    Sorry meant 2' to the waste connection, i understand i need 300 mm above the rim which would be the highest overfill point.
  10. B

    Iron svp

    The svp will have bath at low level, then wc and basin at about 2ft from floor. So 1 ft up from that would be acceptable for a aav?
  11. B

    Iron svp

    A friend of mine wants me to refit there bathroom by removing a none load bearing wall. When this comes down it will leave a cast iron svp slap in the middle of the wall going up into the loft. Can this be cut off at a lower level about 2ft from floor height instead of being up in the loft...
  12. B

    Howdens

    Sounds like your local Howdens favour your competition. I recently won a kitchen quote against a competitor on the same Howdens kitchen. My branch stated they will give me the same price as the other fitter, worked out well for me as he had told them to mark the price up lots more than i...
  13. B

    setting time

    I have a 5 litre tin of sealer so will coat once before and also once after. The floor is 35sqm.
  14. B

    setting time

    Thanks for that. It is light trav so have been using white adhesive. Lastly shall i seal the floor before grouting or after.
  15. B

    setting time

    How long will rapid set flexible adhesive take to set when laying travertine ontop of ditra. I have ufh below the ditra which i won't turn on for 2 weeks after grouting.
  16. B

    1 Large or 2 small?

    That would work but due to the CU being directly above the ovens I'll just have all 3 direct to there mcbs
  17. B

    1 Large or 2 small?

    ovens are going to be in 6mm for that very reason, apart from i have a 100m drum of the stuff that a customer gave me as i present :D
  18. B

    1 Large or 2 small?

    For the sake of the additional circuits they may as have separate circuits, ovens cost 700+ each so whats the point faffy around if warranty is called upon.
  19. B

    1 Large or 2 small?

    All 3 ovens are together in a line of tall housings along with a warming drawer. The ovens pull nearly 4kw each and warranty states dedicated circuit. Yes having a 6 burner gas hob
  20. B

    1 Large or 2 small?

    I could free up a couple of circuits i`m aware of. As stated the boiler added to emmersions on a single 32a 3 32a rings stay a down, up and kitchen 3 20a single ovens as they required 1 40a hot tub isn`t required smokes doubled onto lights. The arguement for 2 boards is good as...
Back