  1. S

    aritech alarm system

    SORRY BREEZER :) It worked, Amazed i hadn't tried that one. The engineer code was 1278 Thanks for all you help Sarah.
  2. S

    aritech alarm system

    tryed it! no sucess. But when i got this first i had no user / engineer codes. I somehow managed to reset it. (no idea :) ) must have involved connecting some wires inside (cant have been too complicated though) or maybe just fluke. If i intermittantly touch the keypad + wire off it's connecter...
  3. S

    aritech alarm system

    Dear Breezer, Yes you were right, bus is also know as data line which is the keypad. I sent an e-mail to a company in dublin who told me to go to install prefs. in the engineer menu and then do an engineer tamp reset. this worked and the system worked perfectly. But you'll never guess, i...
  4. S

    aritech alarm system

    how come you got the panel anyway? (dont want to know from where or who) was it working when it came out? In other words, why the f**k didn't you leave it there any not be annoying my head about the silly thing :) Seriously it was working fine, the building it had previously been...
  5. S

    aritech alarm system

    so i should assume the keypad back tamper is not held in, which it wont be if you have the keypad sitting on your table. It is! Anyway that comes up as keypad tamper. next one will be bell tamper, most Aritech panels have a drawing in the lid showing connections, you will also need to...
  6. S

    aritech alarm system

    Dear Breezer, I have just wired a contact as you described and set it up as an entry exit zone. (I’m only trying things out working off my desk!). It itself worked perfectly but I’m getting an error message “Bus Tamp” and I have to arm the system via the force arm facility. It’s not the lid...
  7. S

    aritech alarm system

    took me a minute to figure out i should be using macro mode but i managed it in the end! I only have one door contact so i will wire it at the end of line version shown in your photograph right? So do i wire the other two ends of this cable into the first and second terminal on the panel...
  8. S

    aritech alarm system

    six of my resistors are coming in at about 4.69K ohms and the other two at 0.992 each approx. I measured them with a meter.
  9. S

    aritech alarm system

    thanks for all your help, i really appreciate it. I already have 8 resistors that came with the panel there not new but look ok. I have more on order from RS, should have them next week. Here are two photographs of the panel:
  10. S

    aritech alarm system

    Perhaps you could try to explain to me again how to wire the zones back at the panel. As that is my real difficulty. Thanks
  11. S

    aritech alarm system

    Thanks for your reply breezer. how exactly does this tamper system work? It sounds like a better system than a global tamper for fault finding at least. The panel actually came out of another building so I dont have the manual and cant seem to get hold of one. I have the user and engineer codes...
  12. S

    aritech alarm system

    so i wire one of the wires from the door contact to the first terminal (zone 1) and the second wire to the terminal shared between zone 1 and zone 2. Am I right? If i am it dosn't seem to be working. Thanks for the reply
  13. S

    aritech alarm system

    thanks for the reply, i'm more confused, sorry! :) In my house i have all the cables for the pir's, contacts, bells, etc. wired back to the alarm control panel. I understand how to provide power to each pir. I was hoping (as i dont have very many) to have each pir / contact on a separate...
  14. S

    aritech alarm system

    Hi guys, I have a aritech cs250 alarm panel which i'm trying to wire up. I have all the cabling already installed in my new house, but i want to try out the system on my kitchen table first. I have the panel, keypad, sounder, pir and door contact. I have the bells and keypad connected up...