Search results

  1. S

    Ariston Genus 27BFFI leaking

    Tightening the nut will not help if a washer has perished or is damaged. I would guess from your description that the boiler leaks whenever you demand hot water from any source for a significant period - not just the shower. Get a bona fide boiler engineer to identify the exact location of the...
  2. S

    Ideal W RS460

    CORGI guy just been. Fault was with the flue. Your diagnosis was correct. Cheers
  3. S

    Ideal W RS460

    Its now switched off. The flue looks clear outside. However, have called a CORGI as suggested. Thanks for advice.
  4. S

    Ideal W RS460

    Have had new pump fitted as was experiencing circulation problems. Slightly better but still some rads cool at bottom so suspect sludge. I will get it fushed. However sometimes after a couple of minutes operation the flame and pilot extinguish. Sometimes the boiler will run for 2 hours. If you...
  5. S

    Icon 23t

    I've had problems with this boiler for years. The PCB was damaged. I could see clearly that a couple of the components were burnt out. Since the new PCB has been installed the boiler is firing, albeit for 5 seconds at a time. The Gas valve was replaced several months earlier on a previous...
  6. S

    Icon 23t

    The parts were changed by a CORGI installer. Can't contact him at moment - must be on hols. I'll keep calling him. Thanks for quick reply.
  7. S

    Icon 23t

    Does anyone out there have experience with Icon 23t combi boilers. Manufacturerd by Glow-worm, sold through Travis Perkins only. The Glow-worm web site does not contain any references to this boiler! In both C/H and DHW mode the boiler sparks and fires for 5 seconds then goes off then instantly...