Search results

  1. D

    replace/repair box Window

    post deleted
  2. Window

    Window

    First floor box window
  3. Box Window

    Box Window

  4. D

    Reverse gear on Auto

    Hello Forum, Ford Fiesta 1.4L Automatic 2010 Sometimes the car will judder when in reverse or not work at all, like it is in neutral. The Shifter is firmly in R. Sometimes it will work if D is selected again and the car is driven forward slightly. My first instinct is to check the oil...
  5. D

    Ventilation

    Thank you for your replies, I took a picture of the fan assembly, which shows the wiring diagram on the outside; I isolated power at the CU. Seems to suggest that the light should be supplied from the fan, through the fused connection. Peter
  6. Vent 4

    Vent 4

  7. D

    Ventilation

    Sparkwright, The fan is supplied via one 3-core + E cable. The cable goes into the back of the fused unit. Blue and Yellow are looped through (not cut), red is cut and connected to the fuse L terminals. I assume the red is Live from the light and the Yellow is the switched live. I have not...
  8. D

    Ventilation

    EFLImpudence, There is a window in the Kitchen, the bathroom is internal and has no windows. Sorry, should have made this clear. Peter
  9. D

    Ventilation

    Thank you Sparkwright. Thanks for the confirmation. Just looking at increasing ventilation as we have a minor issue in the bedrooms. We tend to get anoying brown patches on the ceiling but no visable signs of condensation, average RH is 55-60%. We are on the 1st floor. I might replace the...
  10. D

    Ventilation

    Thank you for your response. Shouldn't all vents through a cavity wall be sleeved? Yes, there is a window. Peter
  11. D

    Ventilation

    Hello Forum, I'm looking to improve ventilation in my flat. Currently, there is a loovent fan in the bathroom, which vents to the outside via a boxed in section going through the kitchen and exiting through a square ventilation brick. The fan is the original installed in the flats...
  12. Vent 3

    Vent 3

  13. Vent 2

    Vent 2

  14. Vent 1

    Vent 1

  15. Vent

    Vent

  16. D

    Damp ceiling

    We have always dried the clothes inside using the dehumidifier, the lease actually forbids the drying of clothes outside :-( We have the central heating set to 21 during the day and a set-back of 16 at night, although the heating only ever comes on at night if it is below -5 outside. I'll...
  17. D

    Damp ceiling

    Hi Dishman, I have been into the flat above, no signs of damp/mould on their wall or ceiling. We have had heavy rain and strong wind, the wall in question faces the prevailing wind so does get completly soaked. The gutter/drains were replaced about two years ago and there are no visiable...
  18. D

    Damp ceiling

    Dear Forum, Owing to the recent weather, I see this is a common topic at the moment! I have searched the forum but most relate to solid walls. Details: 1981 first floor flat, brick cavity, concrete floor slabs. We have what appears to be penetrating damp on the ceiling around the...
  19. Untitled

    Untitled

  20. Untitled

    Untitled