  1. M

    Central heating comes on when thermostat in off position

    I have just taken the cover off the room stat to put a meter across the connections. The perm live is always live but when I cross from Neutral to switched live the meter needle drops down but does not go to the 'off' position. There seems to be permanent current there even after switching the...
  2. M

    Central heating comes on when thermostat in off position

    Hi, it's the same one that was there before on the old boiler, made by honeywell. Sorry can't expand anymore as there is no model number showing.
  3. M

    Central heating comes on when thermostat in off position

    Hi, thanks for the reply. It was installed in March 2010 and was working fine up until she has tried to switch it back on after being in summer mode. The thermostat was therefore working fine up until she changed to summer mode only. The service guy even tested it when he was there and showed...
  4. M

    Central heating comes on when thermostat in off position

    Hi Had a new combi boiler (logic +) fitted last year to a tenants house. During the summer its been on summer mode but now when it is switched back to winter mode the central heating comes on straight away even if the hall wall thermostat is turned below the '0' setting. The radiators also...
  5. M

    Kitchen downlight problem

    Hi Steve, I belive she had to unplug the male connector, so yes I think there is kit form. I asked her what the cable colouring was. The part attached between light fitting and male connector was just two white wires. The other side female to (transformer but up in ceiling so can't see) was blue...
  6. M

    pir lights seems to be staying on permanently.

    Most PIR light have a built in system that if you turn them off then on within 3 seconds, they will stay on for you. This is OK if you have wired them to a switch but a pain if they are mains wired. If they are connected to the mains you will have to turn the power off and leave for 30 seconds...
  7. M

    Kitchen downlight problem

    My Aunts downstairs light started to trip and she narrowed it down to one of the down lights in the kitchen as the bulb had blown and the fitting looked damaged. On advice she has pulled the down light fitting out and unclipped it from the male -female connection (which indicates to be that its...
  8. M

    Water pump

    Hi, thanks for that. I just read something on the internet saying it should only come on with the central heating as the hot water does not use the pump as it is gravity fed. Thanks for your reply. david
  9. M

    Water pump

    The pump in our cupboard next to the hot water tank comes on when we select hot water and leave the central heating off. It then gets very hot as there is no water going through it. Does this mean the wiring is wrong. We only noticed this as we bled the central heating system because we were...