  1. C

    Abuse of Trust by vailiant

    From: A Concerned Installer : Concerned Installer - Vaillant Dear fellow installer, Vaillant is actively using details from guarantee cards sent back by you 8 years ago to generate new boiler enquiries for one of your competitors - Yorkshire based company Help-Link. I have attached the...
  2. C

    Cavity trays and replacement windows

    I am replacing my old wood windows with upvc so have to take some accurate measurements. the existing windows have green plastic cavity trays which are tacked to the back of the windows. Im not sure which is the best way to go about this, weather to try and cut down the side of the window...
  3. C

    Gardtec 350 alarm

    I need to replace the back up battery in my alarm system. I assume its in the main panel. would someone know how to do this without setting the bells ringing (as it drives me mad) I assume i have to put in the engineers code to dissarm it so i can open up the panel. Your help would be much...
  4. C

    Powerflushing.

    Does it really work? Is it all its cracked up to be? Does it really get the system Clean? Would be interested in your comments and observations for those of you experienced powerflushers. Cheers chrisey
  5. C

    Turbomax 828E Diverter

    High guys, Will this diverter come out with just the two hex nuts and the spring clip , or is there other things to release. cheers chrisey
  6. C

    Robinson willey Firecharm

    Any body know where i can get installation and service instructions for this old gas fire please. regards chrisey
  7. C

    Potterton Suprima HE

    Hi guys, Have a problem with a Suprima 50 Cycling every two minutes or so, Same on Hot water, Hot water and heating, or heating. Was the a problem with this model? Your ideas to what it could be would be appreciated. Regards chrisey
  8. C

    Sanicondens Wiring.

    Hi guys, Would anyone know how to wire this Sanicondens (SFA) Please. It has two trailing leads L. N. E. and a Brown, Black, Blue, to do with the alarm. A diagram would be useful if possible. Many Thanks. chrisey
  9. C

    britony combi 80

    pulsating flame (rising and falling) any ideas regards chrisey
  10. C

    Worcester 28si 2 pressure gauge

    Boiler pressure gauge not working even though presurised and fires up, any one had a faulty gauge on one of these or could there be something else causing it not to work. regards chrisey
  11. C

    20deg temp diff on new install

    Hi guys, it always seems to be a bit of a pig trying to get this 20deg temp differential with condensing boilers. On a new install old house how many of you guys are still using the old 15mm copper or are you religously working out your pipework resistance to obtain the correct differential. Or...
  12. C

    Glowworm Swiftflow

    I suspect the pcb, :( but would be interested to hear any other advise/suggestions as to why the fan keeps running on this combi. cheers chrisey
  13. C

    Glowworm Swiftflow

    sorry wrong section
Back