  1. H

    Painted door

    Hi To all Last weekend I painted my front door with the intension of a second coat the following day but alas it did not happen . My question is would I need to rub down again if so could I use course grade steel wool rather than 120 the paint is weather shield gloss
  2. H

    laying sets

    i have 2 questions to ask 1 how wide and deep does the trench have to be 2 what mix of concrete do i need to use? thanks in advance
  3. H

    drive edging

    I want to lay some sets along my drive & have 2 questions to ask 1 how wide & deep does the trench need to be?2 what mix do i need for the concrete?
  4. H

    mid position valve

    thanks for that i have used this method before on rads just making sure its ok on three port valve
  5. H

    mid position valve

    HI All i need a little help i have flushed the system all water came out clean filled the system adding x100. The valve moves ok but hot water on its own and it struggles to get around the coil can i take the valve off by plugging the vent&feed ? i think it may be partly blocked.
  6. H

    central heating flushing

    Hi all i have put x800 in my heating system its been in about three weeks but the boiler keeps cutting out and there is sludge in the header tank. I have drained the system today and all water was clear. Have i done something wrong or is this normal? I have been unable to refill yet as i was...
  7. H

    boiler relacation

    Hi all i am thinking of having my boiler moved from the external wall to an internal wall.the boiler is a potterton prima 80f with a straight flue. On the internal wall it will require a 90 degree bend to to go into the old chimney is this possible or not? thank you in advance
  8. H

    blocked pipe woork

    Hi when I i put the x800 in I left it in for a week on draining it was as black as night so,so kept running water through untill clear.yes the system was hot at the start.the system ran ok for a week.Im now taking rads off and cleaning with a hose its a long job as i have 17 rads .Hope this...
  9. H

    blocked pipe woork

    Hi I have a 3 port valve it is situated next to hot tank when i switch from h/w to c/h I can hear it click the c/h pipe gets hot so do the feed pipes to the rads . the valve is danfoss
  10. H

    blocked pipe woork

    Hi everything just came home yesterday and no heating x800 was in for a week feed to rads get hot but return to boiler does not if i put it on hot water only its no problem
  11. H

    blocked pipe woork

    Hi everyone I have blocked pipes on my central heating I have used x 800 flushed it till the water ran clear. one week later return pipe to the boiler is cold the flow pipe is hot to rads for a while then goes cold anyone have any ideas on how to unblock return pipe. thanks in advance
  12. H

    central heating

    Hi everyone i am in need of some help I have flushed my heating system with with sentenal 800. Ileft it in for a week then flushed it out till water ran clean then added x100.I now have hot rads upstaires cold downstaires. so i was thinking could i use hydrocloric acid if its ok how long do i...
  13. H

    wall support

    thanks for your reply. sorry for not making myself clear. The cracks appear where the window was taken out from the outside wall of the original house,the cracks follow the lines of the outside wall cavity and inside wall across the length of the opening.Hope this explains everything. thank you
  14. H

    insulation

    Hi thank you for your responce but maths is not my strong point so it sounds dutch to me the area is 6mx5m any help most appreciated
  15. H

    wall support

    Hi we have lived in our house a few years now every so often i have to decorate as the ceiling keeps cracking. when a friend looked at it he told me that its where someone has taken an 8ft window for the opening to the extension and there is no support. 1 what sort of support do i need 2 do i...
  16. H

    insulation

    Hi thinking about insulation can anyone tell me how thick cellotex has to be under a susspended floor.The loft has has about 250mm of glass fibre beetween the joists would i be better off replacing this with cellotex. Thanks in advance to you helpfull people.
  17. H

    insulation for suspended floor

    hi folks I need to insulate a suspended floor and Im open to suggestions, some guy reccomended something called cellotex is it any good or a waste of time?if its ok how thick does it have to be and whats it like to install? thanks in advance.
  18. H

    rad valve

    Hi i need to change thermostatic valve on my heatin system ive blocked of the vent& feed pipes with rubber plugs & pulled about two gaallons of water off. but it shows no sign of easing up. have i pulled enough water off or am i doing something wrong. thanks in advance.
  19. H

    combi boiler

    Hi i have a problem with my wocester boiler,it keeps losing pressure 3 so called plumers and a few hundred pounds later still no joy. nobody can find any leaks. does anybody have any ideas they would be most welcome thank you.
Back