    DNO question, new supply

    Yes Bernard green makes a good point, ground source heat pumps could be the way forward for you. Just bear in mind, that most pumps require a 3 phase supply, not all, but most. They don't tend to have a massive start up current, but do require a 3 phase supply. But if your doing the...
  2. W

    DNO question, new supply

    Hiya buddy, Just a few pointers. Looking at the photo, looks like that is a single phase pole transformer. So I would think that is either a 25kva/50kva pt. If your property is 500m from that pt, you should start looking for another lv circuit which may be in the area, if not, your going...
  3. W

    Shower size...............

    Thank You
  4. W

    Shower size...............

    Just a quickie, what is the max shower wattage used on a 6mm twin and earth cable. Many Thanks
  5. W

    Old skool electrician looking for advice

    Thank You for the advice...........................
  6. W

    Old skool electrician looking for advice

    Hello All, I passed my C&G 236 part b in 1993 (last year of 15th edition regs, i think), i served a 5 year apprenticeship and worked in industrial, commercial and domestic dwellings. Since 1994 i left the trade and worked in the telecommunications industry, only keeping in touch with sparking...
  7. W

    Need An Earthing Bible

    Whoops, one more thing, you mention cross bond, would that mean the same as supplementary bonding.
  8. W

    Need An Earthing Bible

    Thanks again, i've got all the info i need. :D
  9. W

    Need An Earthing Bible

    Would that be the same for the kitchen sink and pipework in the kitchen, and would that bonding be 4mm. Thanks again.
  10. W

    Need An Earthing Bible

    Could someone please explain what a normal 3 bed house should have in terms of earthing. Not including the Ring Mains, Lighting Circuits. Would very much appreciate a drawing if possible. Many Thanks :D
  11. W

    Wood colour problem......

    I've just fitted all new skirting in my living room, looking the dogs. The problem i've got is that the door frames were painted with a white gloss. I used a heat gun to remove the paint but the wood underneath is a pink colour, and yes that is PINK... Tried white spirits and it brought the...
  12. W

    Wood colour problem

    I've just fitted all new skirting in my living room, looking the dogs. The problem i've got is that the door frames were painted with a white gloss. I used a heat gun to remove the paint but the wood underneath is a pink colour, and yes that is PINK... Tried white spirits and it brought the...
  13. W

    Radiator problem

    If anyones interested, the problem that i had was due to the thermostat on the radiator. Removed the living room stat and replaced with another, central heating now working fine. Still, a bit suprised since its only been installed 2 years, thanks for the advice.
  14. W

    Radiator problem

    O.K. this is really weird, heating has been working normally again for 2 hours and then the living room rad decides to run luke warm, while the rest of the house works perfectly. I have a boiler stat which is set to 50 degrees, combi boiler......... any help would be really appreciated, ive...
  15. W

    Radiator problem

    What else do you require, not sure?
  16. W

    Radiator problem

    All thermostats on rads. are set between 4 & 5, it is a potterton performa 28i, set at 50 degrees on boiler at 1.5 bar, is this any help? Cheers
  17. W

    Radiator problem

    I have a total number of 7 radiators in my property, which was all installed roughly 2 years ago, all with thermostatic valves. The living room radiator is a double, but recently has decided to offer me only a little warmth. When the heating is swithched on, the radiator is working perfectly...
  18. W

    Installation of cooker, 35Metres from board???

    Thanks for the advice, im gonna look into the insurance and see how much it would set me back, thanks again guys.
  19. W

    Installation of cooker, 35Metres from board???

    i know what your saying breeze, and yes it happens.........people are soon to pass the buck... Only thing i can't understand is the insurance bit, although im not now classed as an electrician, i still work with electrics, fibre-optics, amplifiers, telecomms(pdh ,sdh systems). Nothing over...
  20. W

    Installation of cooker, 35Metres from board???

    Hi breezer, i am a qualified electrician, just been out of trade for a while, so are you saying i've gotta be self employed electrician to be insured......