  1. P

    Adding multiple radiators.

    Thanks Pete, I realise this won't work now!! Looks like I've got a load of floorboards to pull up then! I assume sticking trv's on the new rads , turning them right down in summer would not work either?
  2. P

    Adding multiple radiators.

    The new loop will be between the boiler (downstairs) and the pump (upstairs). Thinking about it, it will be before the 3 way valve also
  3. P

    Adding multiple radiators.

    Hey guys thanks for the quick response!! Never cease to amaze me how people give there time to help other on here!! Extension is one bedroom, kitchen and util so wont bother zoning the system. The new loop will be branched off within 1m of the boiler. The HW cylinder is somewhere in the...
  4. Untitled

    Untitled

  5. extension

    extension

  6. P

    Adding multiple radiators.

    Hi, hope one of you guys can help me? I've just built an extension on my property and I need to add three rads to the system. I have a conventional boiler with 22mm feed/ret. I plan to add an additinal 22mm loop by teeing off each of these 22mm pipes. Feeding each of the new rads off this...
  7. P

    Triton Opal Low Pressure

    Cheers guys thanks for all your help. Will get a new PCB ordered.
  8. P

    Triton Opal Low Pressure

    Yep thats my conclusion too. The somthing on the PCB must be knackered. With regards the switch... I have taken the PCB off and tested the back of the switch. It makes continuity between the legs when the switch is pressed. Anyone know how much a PCB will be? Where is the best place to...
  9. P

    Triton Opal Low Pressure

    Arh.. The stablizer valve is what i referred to as the flow/temp control valve. This works fine. I have just tested the heating elements each gives 12 ohm and the solenoid gives 3.5kohm. Also just noticed that the relay (top one of the two) is sparking at the contacts when the low pressure...
  10. P

    Triton Opal Low Pressure

    Where/Whats the stabilizer valve? How do I check it?
  11. P

    Triton Opal Low Pressure

    Yeah, I have even operated the switch with a screw driver!!
  12. P

    Triton Opal Low Pressure

    Thnaks for your reply... I have taken the shower head off completely and checked the Inlet filter is not blocked. Water flows through the shower no problem at a good rate. Turning the flow/heat control knob towards the hot setting reduces the flow but this is normal. I have tested the...
  13. P

    Triton Opal Low Pressure

    Hi Please can someone help??? My Triton Opal (<2 years old) has developed a fault.... Shower was working fine, however now it now keeps switcing to low pressure whenever i select heat setting 1 or 2. Problem started intermitently but now happens as soon as i turn it on. Water...
Back