Recent content by mercedesjb

  1. M

    Wiring up switch fused spur

    Have taken spur frOm socket to power 3 kitchen cupboard under strips and 12v halagon display lamp via transformer What is the correct way to wire it? And should it be 3A fuse?
  2. M

    Connecting twin and earth to 2 core wire

    I am connecting a transformer with twin mains cable, and I need to join via a junction box to twin and earth from wall switch- what do you do with the spare earth?
  3. M

    recommended electric shower

    I have currently an old mira m8.2 electric shower with right hand pipe entry i am replacing it as too old for availability of spares can anyone recommend a make of shower which would be the easiest to convert. someone has mentioned Redring with right hand entry - but are they any good...
  4. M

    low hot water pressure

    hi boxbasher sorry I should have said;- pressure ok on all other hot taps, including bathroom sink. the offending tap is really loose to turn from closed and the reduced flow only starts after 2 or 3 turns!
  5. M

    low hot water pressure

    i have a problem where the volume/pressure of the hot bath tap has reduced and takes ages to fill could this just be a new washer required? the CH system is boiler and cylinder type-not combi
  6. M

    balancing CH system

    I have tried to balance system by turning all lock shield valves down and openning one by one till they individually get fully hot. however as soon as i get to the 4th or so radiator the rest go luke warm/ or in the case of the downstairs shower room-stone cold i have tried this process...
  7. M

    fitting new Ch programmer

    have replaced my Landis & Gyr RWB200 CH programmer, with a Myson 2MEP 2c Dual programmer All the settings are correct on back I.E. 'I' '7' (5/7 day) and 'P' for Pumped. however when powering up, both CH and water came on , but no display? non of the buttons did anything? with mains...
  8. M

    balancing CH system

    can anyone help me with the best method of balancing the radiators?
  9. M

    bleeding system(literally) !!!

    All sorts of problems with CH and hot water at the moment can only get adequate hot water for a bath if we switch Ch off 45 mins before 2 or 3 rad's upstairs hot the rest either very luke warm or stone cold have:- replaced pump replaced diverter replaced stat on cylinder flushed all...
  10. M

    replacing programmer

    i have replaced my Landis & Gyr RWB200 CH programmer, with a Myson 2MEP 2c Dual programmer All the settings are correct on back I.E. 'I' '7' (5/7 day) and 'P' for Pumped. however when powering up, both CH and water came on , but no display? non of the buttons did anything? with mains...
  11. M

    lack of hot water - quantity and temp' - some rad's cold

    I have had an on going problem for over a year now. basically during the summer months when CH off there was plenty of hot water. Now we have switched CH on all the same problems as last winter have re-ocurred. to start we could only get third of a bath of hot water. radiators not very hot...
  12. M

    EXTRA SOCKET IN GARAGE

    i have an existing double socket in garage, can I just spur off that to another double socket at the other end of the garage. there is only one cable going to the original socket.
  13. M

    position of electricity meter

    we are doing up a house and in the kitchen we are fitting new kitchen units from scratch. because we have knocked some dividing walls down within the kitchen it has left the elctricity meter etc positioned on the back wall but about a foot away from the adjoining wall. we are fitting a 1000mm...
  14. M

    ceiling extractor fan

    i am wanting to fit an extractor fan in the ceiling of my bathroom 1. should it preferably be away from above the bath ? 2. do i need a 'centrifugal' type fan? 3. would i attach ducting and run up to the roof with the appropriate trap and tile replacement? 3. finally how do i connect to...
Back