Search results

  1. N

    Dimplex Storage Heater Repair

    Hello, I have bought a part to repair my storage heater so has thermostatic control again. I want someone to look at my pix to see if it looks like the correct part? Key parts for these heaters appear to be; Thermal Cut-out Charge Controller Bi-metal Damper Limit Accelerator Limit...
  2. N

    Combi Pump continues to run after burner has stopped

    When the burner shuts down the circulator pump on combi keeps running endlessly? The diverter valve is noisy, as it seems to give a "clunk" during program changes. I know there is pump over-run on some pumps, but this never stops? Its on a Worchester oil boiler, but I would think it would be...
  3. N

    Dimplex Storage Heaters

    Anybody know where to get the wall thermostats that go with these old heaters?
  4. N

    C&G 236 part 1 & 2

    C&G 236 part 1 & 2. What year did these two get changed to another C&G certificate? A question for the older chaps on here! :wink:
  5. N

    Baxi Bermuda back boiler and fire fronts

    I have a Baxi Burmuda 552 back boiler and need to change the fire front, would this fit? Baxi Living Flame Fire.
  6. N

    Firebird 90k OIL Boiler intermitant running

    Firebird 90k Combi Boiler. Boiler runs some times and well when it does. Plenty of oil, but not at nozzle. (new nozzle fitted) No electrode spark. (brand new mectron control box + solonoid) thanks
  7. N

    Exterior render with sandstone look

    As it says I need a render that will have a red sandstone look. Does this just mean adding red dye, but how much? What is the right ratio for exterior render?
  8. N

    Adding a Grundfos Pump to Semi-Gravity system

    I just want to check about the position of a circulator I am adding to a semi-gravity plan. I have already added a 2-channel programmer, 2 port zone valve to get independant control. Boiler has got 4 tappings, so it will have the 2 pumps when done. I was going to put it in the flow pipe...
  9. N

    Three phase current and Whole current

    Are there differences between these two and what are there?? I thought they are the same thing? Cheers
  10. N

    Is there a Level 1 2330 course?

    Is there a Level 1 2330 course or is there a pre-requisite to the C&G Level 2 course? Hope that makes sense. :)
  11. N

    Retraining to be Electrician, any point?

    I have everything lined up at the college for training but think there may be little point? There seems to be a huge amount of electrician vans where ever I look! One man bands, multi person companies, multi trade electrical companies! If there are SO MANY what would be the future in this...
  12. N

    Driving is getting worse?

    What is it? Is it the recession or something else. BUT, peoples driving is getting much worse. I am stopping letting people out of junctions myself because I have given up on this courtesy. The other day I came out of a one-way system. Stopping my van to show a guy that he can not drive the...
  13. N

    Fan Isolator in a Utility Room

    You can't have a fan isolator in a bathroom with a fan. Can you have one in the same space as the fan in a utility room? Or kitchen for that matter...? Can they be manual or do they have to be automatic? Cheers
  14. N

    Smart Meters, who's installing them?

    I have seen and heard of Smart Meters (radio operated reading etc) being installed around the country slowly. Anybody know who does it in the Northwest apart from UU?
  15. N

    Qualifications for sparks

    I have a friend (40) how has said he is a qualified spark but does not do into much detail. He said he is registered and can do rewires? If he were, what C&G's would he hold?
  16. N

    Cyprus and its regulations on electricians etc

    Has anybody worked in Cyprus as a spark (or plumber for that matter). Whats the local laws and regulation. Whats the set-up (voltage, system designs, accessories ect). Is it similar to UK regs due to the British influence or more Greek in the installation methods?? I see lots of people with...
  17. N

    Inspection and testing a re-wire in a house.

    I was going to re-wire my house and ask someone to do inspection and testing on the circuits. I have electrical qualifications and daily experience. Do fully qualified sparks refrain from doing this work on others installations. How long and roughly how much would it cost for I&T a 3 bed...
  18. N

    3 Phase Suppling a Lift and CU

    I overheard a job be discussed recently where the incoming supply was a three-phase cut-out and a domestic supply was also needed for the premises. What resulted was the domestic supply taken off one of the phases at the cut-out and not the installation of a second (single phase) cable for the...
  19. N

    Venturi Showers

    Venturi Showers. Who makes them and are they compatible with a poor output combi to improve showering?
  20. N

    C&G 2391 and employment

    If you don't have 83.5 years (joking) in the electrical trade would it still be possible to pass an Inspection & Testing exam?? I have a few years house bashing, but no industrial experience, finding it difficult to get hooked up with any of the local companies for that. Wondered if I would be...