Search results

  1. D

    Vokera and Neat Wiring

    I have pulled the cables out of the box so that you have a better sight of the cables
  2. D

    Vokera and Neat Wiring

    I have a electrician wire in a Gen 3 Nest state and the heating doesn’t work and he can’t get back for over a week. I can’t seem to find a link from the boiler to the nest thermostats. Can anyone give me some guidance so that I can get this boiler up and running with the nest many thank in...
  3. D

    Plastering around fire

    Lime! Next thing it wil include horse hair......lol I did think about lime but I thought that it would be as good
  4. D

    How long to hang doors

    Every door will need a plane put on it to make it fit correctly, you will need to but a closing edge on it as a door should never have a gap any bigger than a pound coin on any edge
  5. D

    How long to hang doors

    The best I can do in a house is 8 doors and ironmongery in a day, which included bathroom locks and clearing up, 8.00 - 5.00 I would not imagine a diy'er could fit this number a make a decent ob of it. If you are a diy'er I would work on one door every 5 days in a day if you want to make a...
  6. D

    Plastering around fire

    I am at the end of my tether with this! I fitted a cassette fire into a existing fire place some ago and fitted it with a Fire plate so that it use the existing chimney, I then dry lined the chimney with a fire line board but after a year the board started blowing out, I therefore had to cut...
  7. D

    Liff 2000 Water Softener

    Can anyyone help please? I have the said water softener in the house that i moved into but there are no instructions for it and i was looking to find out how to set it up as the water still seems very hard. i have purchased a hardness kit and my water is reading 300 PPM however when i go...
  8. D

    twin wall flue

    i am about to install a wood burner and i am looking to install a twin wall insulated liner but as i am installing it in a bungeralow however as i am looking to build on above in two years time can i extend the liner or would i need to change the whole liner? Thanks
  9. D

    Boiler Popping

    the obscure thing is, that every rad is lovely and hot with no cold spots. as it is a vented system i'm thinking it can't be air?
  10. D

    Boiler Popping

    can anyone suggest anything? i have a Potterton Kingfisher MF cf80 which seems to have started popping and a little bit of banging as if the boiler is kettling (boiling). i have turned down the boiler temp but it still does it. what could it be?
  11. D

    House not getting Warm

    never had the problem before, the rads haven't got TRV's and the room stat seems to be working fine. could it be something on the boiler? the boiler is a Potterton Kinghisher MF cf80 just in case you ask the pump is working fine and i have flushed the system
  12. D

    what do i need to do

    about 5 years ago i fitted new dado skirting and stairs and decided to use a timber stain wax on all of it but now it's time to paint it all. what can i do to paint it as i am concerned that the paint will not take to it. any suggestions
  13. D

    House not getting Warm

    i have recently been having some issues with my heating due to a sticky 3 port valve, i have now changed the valve and the heating seems to be working fine however the heating does not seem to get above 21 degrees. i have checked the rads and none seem to have any air in them so i know thay...
  14. D

    Some Real help neded

    Hi All This problem that i am going to list has now been ongoing for about 2 weeks now, so to say that i am getting a hard time from er-in-dors is a bit of a understatement!!! the problem was originally due to the three port valve i had was sticking and thus making the temp rise to about...
  15. D

    Potterton Boiler Help wanted - URGENTLY

    hi all, last night Namesag was able to help me out in getting the boiler running again but after being awake as of 04:00 thinking CHRIST it's cold i had to get up to look at what has gone wrong. the boiler seems to only heat theheating cicuit once the hot water circuit is also on, on the...
  16. D

    Potterton Boiler Help wanted - URGENTLY

    i just want to say a big thank you to Nams as i ended up back filling the system with the hose pipe so that it came out of the vent pipe and in doing so it forced out all the air. problem now solved, all up and running now. Many thanks again
  17. D

    Potterton Boiler Help wanted - URGENTLY

    i agree but after a electrican looking at it and saying yes all wired ok and it seems as if there is a fault on the PCB, hence spending this money. is there a way of back filling it to force out the air?
  18. D

    Potterton Boiler Help wanted - URGENTLY

    tis was my thought. so i opened the drain on the water jacket and water came out ok, i opened the bleed valve on the rad downstairs and water came out. what else could i do?
  19. D

    loo seat query

    i have in the past used a nylock nut on the thread just after the plastic but that comes with the toilet seat to stop them coming loose, and i have never had a problem with them.
  20. D

    Potterton Boiler Help wanted - URGENTLY

    i forgot to mention that when the boiler goes off after approx 60 secs the pump still runs. and if it helps, its a vented system
Back
Top