Search results

  1. K

    Baxi Avanta not showing pressure

    Hi all, My boiler was flashing with an E9 error this morning as is reading 0 bar pressure; but when i topped up using the filling loop the needle didn't move. Could hear water going in, then can hear not much more really able to go in, so have let a bit out of the boiler so not too high (and...
  2. K

    Cooker/hob cable sizes

    Hi all, I'm installing a new kitchen and want to run the new cooker cables under the floor/in the walls before getting a sparky in to hook it all up and into the board once the appliances arrive but need to make sure I leave the right cables for him! I'm putting in a 9.7kw/32amp induction...
  3. K

    Central heating layout

    Hi all, I've just moved into a 1930's semi with no central heating, just storage heaters and an old immersion heater, so i'm planning on ripping it all out and putting in a new Combi system - the only thing is i've only ever fixed/added onto systems before not run from scratch. (Obviously...
  4. K

    Focus 04 mkI: Reverse light fuse

    Hiya, I've got a MKI Focus '04 plate, and my reverse light has gone. I've checked the bulb, that's all fine, so was thinking it must be the fuse? Only prob is i can't work out where the bleeding thing is... can only see the board behind the glovebox, but even then i can't see an obvious...
  5. K

    Replacing a pressure guage on a Worcester 24cdi

    Hi fellas, my pressure gauge is faulty, the dial is completely unresponsive - sitting on the max pressure for a good few months (never discharged pressure out the back or anything) only going back to a true reading when something was done - i.e. letting pressure out thru bleeding/adding water -...
  6. K

    difference between floor tile adhesive and cement mortar

    Hi all, hopefully someone can help on what i imagine is a pretty basic answer!! Having embarked on my first floor tiling exercise - for the bathroom leading onto a small lobbying housing the boiler, i have run out of floor tile adhesive to fnish the lobby area. I still have plenty of...
  7. K

    New cistern leaking at flushpipe

    After spending half a day frustrating myself installing a new cistern I could really do with a pointer from someone more experienced!! I have replaced my old toilet with a new back-to-wall job with the cistern boxed in and the flush pipe cut through a hole in the boxing making the fitting of...
  8. K

    difference between floor tile adhesive and cement mortar

    Hi all, hopefully someone can help on what i imagine is a pretty basic answer!! :) Having embarked on my first floor tiling exercise - for the bathroom leading onto a small lobbying housing the boiler, i have run out of floor tile adhesive to fnish the lobby area. I still have plenty of...
  9. K

    Tiling over uneven concrete

    Hi all, I've got (/had) tiles covering the kitchen floor, leading through a little lobby and into the bathroom. I've taken them up in the bathroom and lobby (may have been hasty in taking them up there). They were layed on concrete, but i'm not sure what adhesive was used as the...
  10. K

    Plaster/rendering inside lean-to conservatory

    Hi all, I have a fairly solid double glazed 'lean-to' style conservatory (with thermo plastic roof) which has a door into it from the house (which i am opening up into french doors). It is plastic and double glazing on 2 sides, with two brick walls (which used to be the outside of the house...
  11. K

    Removing header tank and running off mains

    Hi all, Just in process of purchasing first flat, so not too much experience in these things. I have a massive cupboard, in a tiny flat, that is half filled with a cold water tank - i was hoping to remove this and run off the mains then knock down the brick (but not supporting) wall to...
Back