Search results

  1. N

    Choosing vaillant ecotec 838 or 837

    Hello, I'm in need of a new boiler, my current Ariston while very good is 10 years old and I may as well put the £150 I need for a new secondary heat exchanger towards a new one. My boiler installer (who did my ariston) has recommended a Vaillant as probably the better choice, though he is...
  2. N

    Car wouldn't start, air-con?

    Hello, I've a fairly new honda crv and while stopped waiting for somebody (with engine off) I had the air-con on for about 20 minutes. When I went to start the car there was nothing, the lights were on but the ignition wouldn't try to start. I turned it off for 10 minutes and on retrying...
  3. N

    shower temperature adjustment not working

    Hello, I have GROHE Avensys shower (thermostatically controlled unit for combi-boiler). I've had it a couple of years and it isn't used very much (maybe once a month at best) and in the past month it's just stopped working properly (re: it was working), I've also tried adjusting the...
  4. N

    shower protection/consumer unit?

    Hello, Can anyone tell me what the difference between a 'shower consumer unit' and a bog standard consumer unit is? I've seen them selling as 2-way as well so it isn't just because they only have one breaker :) Or is it just a marketing term? they all seem to cost more than standard 1 or 2...
  5. N

    stabilised and thermostatically controlled?

    Hello, Can anyone tell me the difference between a stabilised and thermostatically controlled electric shower? All I know is I've been told to go for thermostatically controlled to ensure the temperature stays the same. But 'stabilised' is a new term to me, and for all I know it could be better...
  6. N

    insulation board: is one thick the same as two thin!

    Hello, Would 100mm of rafter insulation board (kingspan tp10, celotex ga4000, etc) result in a better, worse or just the same thermal value than 2x50mm boards? I'm converting a loft and I'm now getting round to ordering the insulation. After contacting all the suppliers (kingspan, celotex...
  7. N

    help with fixing item into stud wall cavity.

    Hello, I need some advice on mounting some wall cabinets. I've got a wall bookshelf (http://www.ikea.com/gb/en/catalog/products/80116676) it's 120cm x 35cm by 28cm deep. It weights about 15kb plus whatever I put in (which will probably be cd's). It's going on a stud wall (it was only...
  8. N

    Help with halogen G9 ban

    Hello, I'm a bit confused as to the phasing out of bulbs. I've found a light I want (http://www.ikea.com/gb/en/catalog/products/10086588) But it uses a G9 25w halogen. I can see that frosted ones are being phased out and I read a bit in Osram website about it but couldn't follow what they...
  9. N

    reasonably priced alternative to rockwool

    Hello, To comply with the building regs I need to put in 270mm (well, 300mm is what my building controller wants) of rockwool. I think he's done this because my ceiling joists are 150mm deep. The area is about 12m2. However, what I want to do is board it out but don't really want to cheat by...
  10. N

    alternatives to steel joists

    Hello, I'm having a loft conversion, but the engineering drawings have stated to use the heaviest gauge 10inch steel, which is weighing in at a hefty 90kg per metre. Which in my loft will comprise of 6 lengths weighing quarter of a ton each side (three per side bolted). We are looking at...
  11. N

    priming plasterboard for tiling using acrylic tile adhesive

    Hello, I'm tiling a new en-suite. For the main shower I'm using aquapanel but on the areas not connected to the shower at all (i.e. they won't get wet, but obviously may get moisture), I'm just using standard gyproc wallboards. I want to tile directly onto them, using an acrylic waterproof...
  12. N

    advice on shower extractor

    Hello, I'm in the middle of a new bedroom extension and need some advice on extractor fans for an en-suite. The room is against the back wall and I'm going to fit a zone 1 extractor fan with light. I would say the distance from the fan to the eaves is about 1 metre, in a straight line...
  13. N

    rafter insulation query regarding multi-foil

    Hello, In trying to save space I've been looking at multi-foil for the ceiling insulation on my loft conversion. Given TLX (thinsulate) and Gen-X have BBA approval I figured it must be ok. I'm trying to work out how deep it will actually go to compare against normal insulation but there are two...
  14. N

    converting two one way switches to two way switching

    Hello, I'm converting two rooms into one (knocking down a partition) which means there will be two switches and two lights. What I want is to have just one light. i.e. convert to two way switches. Is there a way of achieving this without rewiring the switches to use three core and earth...
  15. N

    No PIR power but fuses seem ok.

    Hello, I have exactly the same fault (and alarm!) as this post: //www.diynot.com/forums/viewtopic.php?t=141021&start=0&postdays=0&postorder=asc&highlight= Basically I changed a PIR for a new one (A petwise 3D) and all was well, I then took this PIR and replaced an older one. After this...
Back
Top