Search results

  1. B

    Nicobond plastic ply-anyone used?

    I've been asked to tile a large floor in a extension,its a floating floor with wet underfloor heating/spreader plates under 22mm chipwood.I told the customer that it would need ply over the top,he has however recently purchased all the tiles (750x750) and the supplier has shown him the plastic...
  2. B

    Slate flagstone over heated floor-questions..

    Ive been to look at a project for a customer today,part of which is to lay approx 120 sq mts of Stonemarket slate style stone slabs internally-something ive never done before,i got a few concern's regarding the following:- The sub floor is suspended timber incorperating wet underfloor...
  3. B

    Electric water heaters/boilers -info

    Hi guys,my parents liveing down in cornwall have no gas supply and currently rely on storage heaters/immersion heater for heating and hot water.They have asked me to look into alternatives and i've noticed screwfix/plumbfix listing the Galaxy Powerstream range which look as if they would be...
  4. B

    immersion heater wiring

    guys a quick ask please,during re-fitting a bathroom i've been asked to change the old immersion heater(no longer works),noticing that at some point the wiring has been hijacked to power the shower pump...i can run some new cable direct from the box and install a new outlet no problem-is this...
  5. B

    Glowworm spacesaver-problem continues...

    Hello again all,well as an update to my origional posts i've had the system powerflushed but made little differance.i've still got a problem(or not) in that the boiler runs for abuout 8 to 10 mins then cuts out,i've noticed that when the boiler cuts out turning the room stat up further has no...
  6. B

    Boiler or programmer fault-or not ??

    As an update to an earlier post last week-Glowworm space saver boiler/Honeywell programer,the system has now been left alone(!) for a few days and on the whole working better than before,i'm still convinced something just aint right somewhere-can the HW tank stat overide the CH stat-perhaps if...
  7. B

    Glowworm boiler/Honeywell programer-fault?

    I'm hoping someone can offer some wisdom here-whilst working on a property i was asked to look at the CH system-its a glowworm spacesaver 30 installed in 84,all rads are controlled by trv's bar one in the bathroom,microbore pipe feeds to rads(10mm),honeywell st699b controller and roomstat in...
  8. B

    travertine wet room problems

    In may 2009 i did a bthroom conversion for a very good customer using travertine honed and filled tiles(customer choice),bal natural stone adhesive and bal superflex grout-all supplied by topps tiles.The basic plan was rip out old suite and shower and walls,make good and check...
  9. B

    sound proofing

    does anyone know of a suitable sound proofing/acoustic reducing cladding or system on the market(plasterboard system aside). i am working on a old property ste about 30 feet back from a main trunk road,and although the double glazing is effective to a degree th e customer has asked me to...
  10. B

    potterton 10-16 problems

    i'm working on a property which has a potterton 10-16 boiler,randall 4033 programer and microbore pipework(!),its a 3 bed semi-boiler in kitchen-hot tank on landing-cold tanks in loft.we were asked as part of the works to add a radiator in the conservatory and fit trvs to some of the existing...