Search results

  1. J

    40mm Plastic Waste Pipe into 4" Cast Iron.

    Hello All I want to replace a lead waste Pipe with 40mm plastic because it has leaked and caused downstairs celing to fall down - Ooops. The lead is connected to cast iron below the bathroom floor. I could probably push the plastic waste at least 2' into the cast iron pipe if necessary...
  2. J

    Flushing/Filling new instalation

    I know why they do - It is a chance to do 4 years of no work, constant partying and lie in every day until 2pm! I know this because I did it. To be honest I think that I would prefer a practical job, but I satisfy my need for practical work by spending my spare time doing DIY. Anyone...
  3. J

    Pebbles for Gas Fires

    I think the answer to your question is that you can't replace the coals on your fireplace with pebbles. The fireplaces with pebbles come with them. And all imitation coals/pebbles are fireplace specific. You would have to replace the whole fire to get the pebbles. I think B&Q does a gas...
  4. J

    Flushing/Filling new instalation

    Hello I have installed my combi on the wall, installed all my cold and hot water pipes and my pressure releif pipe as per all the help from you lot (so thanks). I had a corgi man round who said on the phone he didn't usually touch DIY jobs! When he came out he said "Thats a no bad job"...
  5. J

    Gas - Copper Sleive

    Hi all I am having a gas meter put in next month. I will be connecting it up to a fire, hob and combi. I was just wondering if anyone knew if there would be a problem with leaving a 15mm pipe under the kitchen floor to insert the pipe for the hob. The reason why I want to do this is to...
  6. J

    Combi Safety Valve

    Thanks for all the very useful info. there is a path right below the wall where my boiler is. I assume this means that I cannot just leave an open end to here. There is a 40mm drain from the Kitchen running through the room. Can I connect in to this? And if I can does anyone know...
  7. J

    Combi Safety Valve

    Hello I am installing a vokera compact 28 and am not 100% sure what to connect the pressure relief safety valve to. Any Ideas? Before you ask I am getting a Corgi registered installer to connect the gas and commision the boiler. Help appreciated.
  8. J

    Plastering Ceilings

    I just wanted to say that big strong boys were a bunch of bodging poofs.
  9. J

    Laying cables

    The correct way is under the floorboards. I have just rewired my whole flat and I went below the boards. However this can be a lot easier said than done. Especially if your boards are tongue and groove like mine were. Behind the skirting will just work the same and provided you...
  10. J

    Tracking copper pipes into wall

    Thanks for the info. I feel daft for not thinking of it myself! :oops:
  11. J

    Tracking copper pipes into wall

    Cheers for the help. What will I have to do with the joints then as I will need an elbow to bring the pipes out of the wall?
  12. J

    Tracking copper pipes into wall

    Hello Can anyone tell me if it is ok to make a track in my plaster to install copper pipes for a towel radiator above the bath. The plaster is plenty deep enough for 15mm pipe. Will I have to coat the pipe in anything? Can I just plaster over it again or will the pipe heating up and...
  13. J

    Cast Iron Waste Pipe

    Does anyone know if it is possible to fit a section of plastic to a cast iron Waste pipe? I need to break into the pipe lower down than where my current kitchen waste joins on. I live in a 4 story block of flats and I'm on the 1st floor. Will this effect my neighbours above/below...
  14. J

    Fire Door

    I need to fit a fire door to my new kitchen to get a completion certificate from Building Control. My flat has still got all the original hardwood doors which I got stripped and look great. Unfortunately all the fire doors I have found look crap and I have already bought an original...
  15. J

    Pulling down a supporting wall

    Hello everyone Thanks for all the help. I have now knocked down all the walls as per my plans. I promised that I would keep you updated on my progress. It all went to plan although it was heavy work. It took 4 days to pull down the 3 walls and istert all the structural work. Not bad...
  16. J

    Pulling down a supporting wall

    Sorry to bring this one up again but I am going to start the work this weekend and I don't know what size of a skip to order. The walls are all single brick (150mm thick) and the main wall measures around 7' x 11' there is also 2 doorways to come out. Does anyone have any idea how to work out...
  17. J

    Earth wire to fuse box

    Thanks for that lads You have set my mind at rest. I think that my system will be ok but I will get an electrician in to do an impedence test as you reccomend. That should still be a bit cheaper than a full rewire! Cheers again
  18. J

    Earth wire to fuse box

    Thanks for all that info lads. Unfortunately I am still not entirely clear on whether I have a problem. I have lots of earth terminals in my fuse box which all the earths from the rings, etc are connected to. The problem is that in the main earth connection there is a very old lead...
  19. J

    Earth wire to fuse box

    Hi Anyone know what the main earth cable from a fuse box should go to? I am rewiring my flat into the existing fuse box and am concerned by the fact that my earth wire just seems to be connected to the wall. Help me I don't want to fry myself. :evil:
  20. J

    Pulling down a supporting wall

    Thanks for that lads. I've decided to give it a shot. My local Hire shop does strongboys and props for £4 a week as you said. I'll keep you up to date on my progress, just in case you're interested.
Back