Search results

  1. M

    sanyo em-s2298v microwave fault

    im looking for a little help with my microwave, just cooked as normal and now when i close door the fan/ turntable and light stays on, its not cooking tho just staying on , tried removing plug and leaving out but its like its jammed on, if i set timer etc it cooks as normal just when it...
  2. M

    drain rods stuck

    got a problem with my drain rods ! plastic drain runs under house and from first rodding point all went well on a straight run back of house to front drain, then i put rods in at side of house next to my utility room in house as sink had occasionally blocked rods and plunger got half way down...
  3. M

    vokera option urgent help please !!

    guys, got a vokera option playing up, had a thermister problem which was sorted tonight. fired up no probs all ok, then i put casing etc back together and solid red light fault came up once i restarted ? flashing red is thermisters etc, so doen all the checks, fan and pump runs and as soon as...
  4. M

    price right heating

    just a note for anyone who uses or had seen them on the internet !! DO NOT USE !! Ordered a pcb 2 weeks ago, they debited the money and no pcb arrived , called them they advised it was obsolete so money would be reunded. was unhappy as no phone call or mail to advise and i paid for next...
  5. M

    worcester 9.24 pcb urgently required

    guys, looking for a pcb for a worcester 9.24 its the older pcb thats now obsolete with worcester part number 87161463240 PCB W9355B .. seen a couple but never bought from any of these places and prices vary, anyone uesed any of these ?? http://www.boilerpart.gbr.cc £54 from here...
  6. M

    worcester 9.24 c/h problems

    Guys, got a worcester 9.24 (47-311-07) with the old relay and 1 circuit board, not the one with 2 boards !! The problem im advised is intermitting, the boiler will not always fire on demand for central heating, but if the customer runs the hot water this activates the boiler and the c/h...
  7. M

    urgent info required install new shower

    GUYS, Need some urgrnt help.. recently bought a triton barbell shower, comes with all fixings etc but it has the offset connections, the problem I have is if I connect this to my gyproc cavity wall using a 1/2 inch bsp connector I have barely enough thread coming through to connect shower...
  8. M

    ISAR HE24 COMBUSTION CO READINGS VERY HIGH !!

    Folks, went to an ISAR HE24 today and after fitting the new pcb telganed it, the CO reading wnt skyhigh, removed the cover and reading went right down, still around the 0.0010 mark but well passable.. checked everything, all seals and visually the flue looked fine, Ideal suggested replacing but...
  9. M

    ideal isar diverter valves

    Guys, had 3 of these this week with rads constantly heating due to sticking diverter valve bodies, all 3 were with wilo head (plastic cartridge) has anyone tried just cleaning these and lubing ?? really cant see why they stick so easy and never actually tried just lubing and cleaning but...
  10. M

    where to sell unused parts ?

    folks, have a few parts im never gonna use, stuff that was for a contract my company lost, sold a few bits on ebay but looking to see if anyone knows somewhere to sell back to as these parts will no longer be required !! got 1. 1 x potterton lynx electtronic gas valve 2. 1 x worcester...
  11. M

    OCEAN ALPHA CB24 HELP

    Guys, looking for some urgent help on a cb24 dhw diagphram basically went to one today, changed flow switch didnt work, stripped dhw flow diagphram section, found nowt wrong and put it back together the way I thought it should go, (METAL SIDE FACING OPPOSITE SIDE TO DIVERTOR SECTION...
  12. M

    vokera excell 80 sp Divertor valve problem

    Guys, got a passing divertor valve on a 80SP VOKERA. Had this problem with a linea and got the service kit, pretty basic repair. got the kit for the EXCELL / ECLIPSE and just wondering as it comes with the diaphrams etc, do I just replace the divertor section and how easy is it to do so...
  13. M

    IDEAL CLASSIC FAN ISSUE

    Guys, been to a few ideal classics lately and as most will know the fans have a small plastic propellor on the top, for cooling purposes to the fan motor I would presume ? anyway as most will know/ have seen these plastic propellors all tend to go brittle and break off thu time Just...
  14. M

    BAXI 80E COMBI RISING PRESSURE

    Guy's .. quick one for you's.. Mate called tonight at a Baxi 80e combi.. hes an engineer but works on Meter installs so not into FF... PRESSURE WAS RISING... Usual checks of exp vessel done, called me back saying pressure was rising when system not running, advised to check filling loop...
  15. M

    Plumbing / gas engineer national rates of pay

    Guys, having a little dispute at work over wages etc . work for a large maintenance company just now and normally our wage rises etc are set with Scotland and Northern Ireland (SNIJIB) suggested rates of pay. Now our bosses are stating these rates are only applicable to PLUMBERS and not GAS...
  16. M

    BEST COST EFFICIENT WAY TO HEAT STORED WATER ?

    Keep getting asked this by tenants and have no real answer so wondering what you guys think OR KNOW ?? Ok gas heating stored water, normal family use whats the most cost efficient way 1. H/W ON CONSTANT stat set to 55-60 2.H/W ON AT SET TIMES OR BOOSTED AS REQ 3.H/W ON CONSTANT +...
  17. M

    NO HEATING DOWNSTAIRS !!

    Quick one guys !! just been to my old neighbours and heating upstairs works when she puts c/h and h/w demand on.... no downstairs heat at all... suprima 30 system with mid position valve ... checked the pump and rocked it form 1-3 a few times,,, checked the valve and thought the head...
  18. M

    IDEAL ISAR HELP !!

    Guys !! was at a job this week, no C/H on an ideal isar.. found power going to the divertor valve but it would not operate so ordered a new divertor valve head... when I arrived to fit the new part the boiler was operational again and heating working fine... anyway changed the valve and...
  19. M

    SUPRIMA 30 BLOWING PCB FUSE

    Guys... I dont have my multimeter or fuses handy tonight when called to a mates house , suprima 30 s plan system , no lights on.. checked pcb and fuse had blown, had 1 x 3amp quick blow in my box so retried but disconnected GV and Fan, turned the boiler control knob to 0 no controls calling...
  20. M

    POOR HEAT AT RADS

    Advise please.... My mate has an old BAXI FIRE/BBU and over the last couple of months the downstairs rads werent heating too good. Went had a look and thought symptoms of a sludged up system, anyway added sludge remover and returned 4 weeks later and drained, when I drained the water was...