    Leaking unvented cylinder

    Bump ... Any ideas ?
  2. F

    Leaking unvented cylinder

    The replacement thermstat was a like for like as thd original one supplied with the cylinder as was about £80 . Like i said before though i dont think it was thd thermostat before and definatly not now as its dry inside and on threads etc
  3. F

    Leaking unvented cylinder

    Hi all , i have a gledhill indirect stainless lite solar (not connected up or used atm ) unvented cylinder which has got my plumber baffled . About a year ago the cylinder started leaking through a small opening in the insulation at the bottom of the cylinder .my installer couldnt see where it...
  4. F

    direct to drain downstairs toilet

    Installing a ground floor toilet and I am trying to find out what the maximum distance this can be from the main drains ,its going to be directly connected to drain ,not to a soil stack ,all I can find in the regs is the maximum drop allowed on this setup which is it has to be less than 1.3 m...
  5. F

    Main earth bonding

    I have two points of entry into my house for my mains water , the main one comes in to feed the unvented cylinder and the rest of the house mains water , the 2nd one comes in just to feed the kitchen sink and outside toilet . Do i need to bond the kitchen feed as well , i have installed the 10...
  6. F

    Atag service required

    We need our Atag 38q system boiler servicing . If there are any Atag experianced gas engineers in and around Mansfield , nottinghamshire please get in touch
  7. F

    thermostatic mixer shower

    shower plumbing diagram does have a pressure regulator on it , but doesn,t state at what mains pressures you would need to fit one .my unvented cylinder does have a pressure reg fitted but its on the 22mm cold feed into the cylinder , so i would have to branch off after that point and i...
  8. F

    thermostatic mixer shower

    just installing a mira realm mixer shower , we have a system boiler with a unvented cylinder . is it best to give the shower a separate 15mm feed pipe for hot water which is branched off the 22mm hot water pipe which goes to our bath ,there is also a 15mm hot water pipe nearby aswell , the 15mm...
  9. F

    drainage system suitable for tiled porch/veranda

    i am currently in the process of relaying some old edwardian quarry tiles on a porch floor that is partially open to the elements .i am thinking of putting in some kind of water drainage combined with a suitable fall in the floor level to help get rid of the rain water .there is a water drain...
  10. F

    porch/veranda floor spec

    i am in the process of renovating a edwardian house with a open porch/veranda , there is a roof but the floor area is partially open to the elements. i have taken up the old quarry tiles and found the concrete floor to be full of damp with some voids so i have removed that as well. i now need to...
  11. F

    suitable tile for woodburner

    i am currently preping for a wood burner to be fitted to my fireplace , i was thinking of having slate for the hearth base , the slate tiles i have seen are about 8-10mm thick , will these be ok as the wood burner is 9kw max, & is it best to lay them with fire resistant tile adhesive , cheers...
  12. F

    limescale inhibitor

    thinking of putting one of those limescale inhibitors on my incoming supply , whats the general view of these things , we are in a hard water area so would it be usefull for making our appliances last a bit longer etc
  13. F

    New Water supply pipe

    We are having our old lead water supply pipe replaced with plastic . we recently had a new system boiler installed complete with unvented cylinder . where would the most suitable connection point be for the new supply . would it be best coming virtually straight into the cylinder supply pipe...
  14. F

    Lead replacement

    We have a long run of 55m of half inch lead pipe on our water supply. The pressure and flow are not great so we are thinking of replacing the whole lot with plastic. Quoted £1250 using the mole method so there is no trenches dug out . Price seems ok but we are going to block pave the area...
  15. F

    atag q 38s system boiler

    atag tech bloke said they needed to be wired type. as volt free connection required . could your give me a bit more detail about how to wire these up ( wireless type ). system has 2 zones for heating so i have got two stats one upstairs one down . i need the info as i will check my electrian...
  16. F

    atag q 38s system boiler

    Hi , can i use honeywell cmt 927 wireless stats with atag q series system boiler , the property has two zones for heating & one for HW . atag say they must be volt free to boiler connection , will these be ok or do i need differant stats .
  17. F

    Atag , viessmann 200 or worcester bosh

    stiler is those prices , with or without vat.
  18. F

    Atag , viessmann 200 or worcester bosh

    just to get this thread back on track , the atag a series is £1150 the q is £1850 & the viessmann 200 is around £1100. the atag a series is 32kw but will modulate down to 6 , as will the 26kw viesmann , the 25kw q series atag will go down to 4 . problem is its a lot of dosh . was gonna go for...
  19. F

    Atag , viessmann 200 or worcester bosh

    if i were to go with the atag A320 system boiler , which controls would you reccomend , the atag contolls look expensive , could i use say honeywell instead or would i need the atag ones for the weather comp . my system will be zoned upstairs + downstairs
  20. F

    Atag , viessmann 200 or worcester bosh

    the atag a series boiler is 32 kw output but it does modulate down to 6 kw . so am i right in thinking it would be ok even though i only need around 25kw . also i see you are in notts , do you fit atag or viessmann.