Search results

  1. pete26671

    Flomaster backplate

    Hi i was hoping for a bit of advice. Have just tried to put central heating on and the programmer came off the wall . As i was about to refix it back i have noticed a loose yellow wire and am unsure as to where it goes as there are 2 free terminals
  2. pete26671

    How many 100mm blocks

    Hi ppl can anyone help . Because I'm absolutely useless at maths I can't work out how many blocks I need . I am rebuilding our kitchen from wood frame to block but am having trouble trying to calculate the overall size it is 12 ft long by 8 ft high and is 8 ft wide and luckily has only 3 walls...
  3. pete26671

    Sunvic MP2 Electro-Mechanical Programmer CB3303

    Sunvic MP2 Electro-Mechanical Programmer CB3303 does any 1 have a photo of how this programmer is wired up as im having problems and dont want to kill any 1 lol
  4. pete26671

    Sunvic MP2 Electro-Mechanical Programmer CB3303

    Sunvic MP2 Electro-Mechanical Programmer CB3303 does any 1 have a photo of how this programmer is wired up as i cant find 1 anywhere any help greatly appreciated
  5. pete26671

    MANUAL 3 PORT VAVLE

    can any 1 tell me if it is still possible to get hold of a manual 3 port valve ..????????? any help would be appreciated thanks
  6. pete26671

    NO CIRCULATION THROUGH RADS

    Hi i am having trouble with my ch sys i have now drained the sys down twice but an unable to get circulation around the rads. i get no heat to any rads but if i undo a drain off on one of the rads it does get hot but then goes cold after retightening please help [/u][/b]
  7. pete26671

    Is this the same programmer

    [/b]Hi guys can u help me with a little problem ,I have a sunvic programmer for my centrol heating system which unfortunatly has decided it doent want to work properly .the problem i have is which programmer to replace it with i have contacted sunvic and they have said that they think i have a...
  8. pete26671

    bathroom quote

    how much would people expect to be charged for a standard bathroom suite ? _______________________________ Lynda, moderator Please see forum rule 9
  9. pete26671

    CENTRAL HEATING HASSLE

    hi i hope u can help at the weekend i had to install a new pump as the centrol heating system failed . after installing i refilled the system but only the top rads were working even after bleeding ,so i emptied and refilled as i thought that it might be a air block but after refilling again i...
Back