  1. J

    Fitting 3 x 2kW panel heaters in a flat.

    Thanks, I was just being lazy - OSG's outside in the van!
  2. J

    Fitting 3 x 2kW panel heaters in a flat.

    None were fitted before, the previous occupant used plug in oil filled radiators.
  3. J

    Fitting 3 x 2kW panel heaters in a flat.

    Like the thinking! Is 20A breaker for a 2.5mm radial? I'm not sure of the installation method?
  4. J

    Fitting 3 x 2kW panel heaters in a flat.

    Hi, I've got 3 electric panel heaters, all 2kW with built in timers and stats to fit in a small 2 bed flat. there's a single ring main throughout. It would be very convenient to feed them all off the ring mains circuit via double pole FCUs. Total max current drawn is going to be in the region...
  5. J

    vaillant ecotec plus problem

    OK. Just in case you're interested. I got the installing company round who said 'yeah it's broke' and told me it needed a new seal, a sensor, plastic air intake and front cover and charged me 60 quid for the privellage. He then went off and ordered the parts. An independent plumber...
  6. J

    Digital TV Wall Plate

    Try JW Hardy Communications in Stechford, Birmingham he's got everything like that and does mail order too.
  7. J

    vaillant ecotec plus problem

    You must be psychic Agile! I've not mentioned whether it'd been serviced or not or if the warantee had been registered. Also, I'd not ignored any overheating as to my knowledge there'd been none. Also, suerly the installers ( a big corgi company - who I wont mention by name) should...
  8. Untitled

    Untitled

  9. boiler

    boiler

  10. J

    vaillant ecotec plus problem

    I forgot to mention - the top centre of the boiller is REALLY hot and has gone discoloured.
  11. J

    vaillant ecotec plus problem

    ok, 1 - F64 2 - F22 3 - F22 4 - F22 5 - F22 6 - F75 7 - F75 I don't suppose it's possible to find out when these occured?
  12. J

    vaillant ecotec plus problem

    I've had this boiler for about 3 years with no problems. Over the last couple of days the domestic hot water has not heated up properly - i.e. it has only got luke warm. I watched the display and although the water is set at 60 degrees it only reaches about 46 before the burner cuts out and...
  13. J

    Extractor Fan

    What cable have you installed to your fan? you need 3 cores + earth. Ususally from the ceiling rose: red/brown - permanent live, yellow switched live, black/blue -neutral. If you haven't got the 2 live connections it wont work.
  14. J

    new oven and hob

    Thanks, So do I need to replace the 20A switch with a 13A fused spur, or is the 13A fuse in the plug ok?
  15. J

    Optima G3 Alarm Control Panel beeps?

    Europlex, How come people dont believe you when you tell 'em. I reckon I've made about £500 over the years from this exact thing.
  16. J

    Optima G3 Alarm Control Panel beeps?

    I've come across this time and time again. Take the batteries out of your smoke detectors and see if it still happens. BUT PUT THEM BACK AFTERWARDS! Unless you have mains operated smokes with back up batteries, in which case put new batteries in.
  17. J

    new oven and hob

    Hi davelx In answer to your question, the 6mm cable is clipped along the garage wall from the CU and back entry through the wall to the cooker control in the kitchen, then back out again into the garage, clipped along 1m and through the wall again to the cooker connection. One more...
  18. J

    new oven and hob

    I'm just refitting my kitchen and am installing a 7.2kW inductiuon hob and 3kW single fan oven. At the moment there is a 6mm cable from a 45A breaker in the CU to 45A cooker controller to the hob. The oven is fed from the kitchen ring main via a 20A double pole switch. Does all this sound...
  19. J

    oven & hob

    I haven't actually got the oven and hob yet so I don't know the output. the oven is A rated for efficienct though - if that means anything.