Search results

  1. S

    Dry Ridge Tile

    Hi , i am a heating installer involved on a new build of apartments the client wants the flue to go through a ridge vent outlet, the spec ridge is a forticrete dry system, my question is we are looking at using a valliant boiler with a ridge terminal flue, there is a ridge that is used for this...
  2. S

    Gemini Gulf Stone Tiles

    Hi Guys, Im a plumbing and heating engineer , done fair bit of tiling, my sister wants a new bathroom she has picked the gulf stone tile, u know the one with the sparkles in .Any advice on the installation of these ,adhesives , grouts, do i need to seal.I was thinking of a rapid set...
  3. S

    Cable size for heating spur

    Hi Guys im a heating installer, just a querie , what size cable do you need supplying a spur to feed a boiler,i was under the assumption that 1.5mm T & E is sufficient , just an electrician doin an inspection and testing and he has noted it needs to be 2.5mm.What is the crack with this one,any...
  4. S

    Adhesive

    Hi , what adhesive brand would anybody recomend for a 300mmx600mm wall tile , any ready mix available or will it have to be the powder mix? Any thoughtys appreciated.
  5. S

    Earth requirements

    Hi all im a heating engineer , brought in my sparky to add fuse spur, its a tt system no earth to gas meter , fair enough , but he also said water needed earth to is this required ? Cheers
  6. S

    epoxy resin

    hi all is there anything can be done with grout in my shower area it was white epoxy now its kinda yellow
  7. S

    Bricky tool again

    Ok men hows it goin right i need to build me self a front garden wall , pillars and all that , im looking at the dare i say it the bricky tool ,anyone know if i can use for a 9 inch wall , or shall i bite the bullit and do it the normal way,looks like i can save time money and have a decent job...
  8. S

    Zone valves on heating system

    Hi all im going to be upgrading a heating system,installing extra rads upgrading pipe work etc.The boiler is a worcester 400 rsf electronic higflow.layout is boiler has integral programmer for hot internal store and for central heating.What i want to do is to have two zones for the central...
  9. S

    Baxi Duo-Tec No Hot Water

    Hi havent had much to put right on these boilers have one that i have o go to and has no hot water but ch fine, customer says that the hot water neon doesnt come on when she runs the tap so im suspecting the hall effect sensor, any thoughts anybody?
  10. S

    Baxi Duo-Tec Codes

    Hi having just installed one of these have fitted many the customer has said it has flashed up code 168 ,just wondering before i get in touch with the baxi tec guys does anyone know what it is, i know there are several hidden codes o these but aint seen that one before . thanks
  11. S

    Baxi 105he instant

    Hi fellow gas installers right baxi guys on here. I do a lot of work for housing co-operatives, they have these nightmare boilers in ,and are about to come out of warranty even though baxi extended the warranty due to amount of problems. Most common fault i come across is the pre heat...
  12. S

    Baxi 133 noise

    Hi there im a gas installer ,have a prob on a baxi 133 he plus ,when the hot water is ran after a while once the boiler is starting to get upto a hot temperature it starts making a screeching noise , figure it may be the diverter valve and them o rings again, or poss the pump not circulating...
Back