    23vc posted the thread Rockwool slabs for 4x2 CLS in Building.
    Got a 4x2 CLS stud wall to insulate, board, skim etc. Will use the rockwool acoustic/rwa45 slabs/knauf acoustic slabs. The 100mm size of...
  • 2
    23vc replied to the thread AIB or Wood?!.
    Plasterboard/cement board/asbestos. Gut feel is not plasterboard as the paper face tends to go brown over the years, and just looks more...
  • 2
    23vc replied to the thread Bedroom insulation.
    You don’t need a vapour barrier on a party wall. Whether you need one on the external walls may be up for debate, but from what I...
  • 2
    23vc replied to the thread Bedroom insulation.
    Not sure what you mean by concrete slabs and concrete studs, but if it’s a party wall, forget vapour barriers or thermal insulation and...
  • 2
    23vc replied to the thread Bedroom insulation.
    You could try, just make sure it’s not near a joint which could break and cause an involuntary drain down… At a push could also just...
  • 2
    23vc replied to the thread Bedroom insulation.
    pretty unlikely, better doing it properly and re-piping it. And surely you want to be moving it out more than 2cm based on the above?
  • 2
    23vc replied to the thread Bedroom insulation.
    Foam gaps - yes Shave PIR - I wouldn’t, as I said above, just do it in such a way as that’s not needed
  • 2
    23vc replied to the thread Bedroom insulation.
    Assume that’s a timber frame with block infill? There’s loads of ways you could do it, could start again with a 2x2 frame with say 50mm...
  • 2
    23vc replied to the thread Bedroom insulation.
    If space, to make a noticeable gain I’d deffo go with more like 50-100mm PiR, framed/trapped to existing battens/masonry with battens...
  • 2
    23vc replied to the thread Carport Fireboard Reattachment.
    Pink fireline plasterboard? If so, use bugle headed drywall screws. Rather worrying that any screws have “fallen out” which shouldn’t...
  • 2
    23vc replied to the thread Boarding over ceiling with cornice.
    Either stick/dab 9.5mm/12.5mm boards on nice and tight, or glue and bonding coat then skim, or a bonding/skim mix. How deep the artex...
  • 2
    Are you talking about an opening in an existing house wall which is going to be too big for a conservatory which is going to replace an...
  • 2
    One of the key characteristics of cavity bats is they supposedly don’t wick moisture. But they don’t tend to get used below dpc much...
  • 2
    23vc reacted to cdbe's post in the thread Thermolite block replacement - advice wanted with Like Like.
    Can't see why you'd replace any of that.
  • 2
    23vc reacted to Ivor Windybottom's post in the thread What size jack-hammer? with Thanks Thanks.
    In that case I'd recommend just buying Screwfix's Titan beast. It will probably cost less than hiring. I have one too, it's pretty...