    Alpha 240P problem

    Further examination of the failed sensor showed that the plastic moulding had a severe crack/moulding fault and was intermittently functioning. In fact, it fell apart during examination and did reveal a moulding fissure. Never mind, all is now well.
  2. 2

    Alpha 240P problem

    All seems OK now, it was the CH temperature sensor. Thanks for the excellent responses which guided me to a successful outcome. very much appreciated.
  3. 2

    Alpha 240P problem

    About a month ago, I had been having several problems with my Alpha 240P boiler. Initially, a relay on the main board was sticking and not allowing the boiler to fire up. I replaced the board and this resolved the problem. However, a new problem has arisen. When the heating comes on in the...