333rocky333's latest activity

  • 333rocky333
    Bypass the sensor to try, light, looks simple as joining the two reds
  • 333rocky333
    333rocky333 replied to the thread PATTRESS IN LOFT.
    Not always, if your connecting to an existing circuit thats not Rcd protected, as in older ptoperties you can use an rcd socket or an...
  • 333rocky333
    333rocky333 replied to the thread PATTRESS IN LOFT.
    only if connected to an rcd protected cicuit
  • 333rocky333
    333rocky333 replied to the thread Armoured cable termination.
    yes it does, i believe the op said there was already an rcd at the source
  • 333rocky333
    333rocky333 replied to the thread Armoured cable termination.
    You could gland off into an external box at low level, strip the swa really long and run up to the Dist Board in flexi conduit, maybe...
  • 333rocky333
    333rocky333 replied to the thread Armoured cable termination.
    Safe zones don't apply to earthed armoured swa,
  • 333rocky333
    333rocky333 replied to the thread Armoured cable termination.
    Possibly me, I suggested glanding off behind the consumer unit, depends how one interprets the regs and whether the actual gland needs...
  • 333rocky333
    333rocky333 replied to the thread Armoured cable termination.
    Why would you want a join and T and E, would it not be better to take the swa direct to the consumer unit, personally I would maybe...
  • 333rocky333
    333rocky333 replied to the thread Sockets in thin walls 7 cm.
    Think they were called clinker blocks used a lot in the old days for non structural partition walls, i flushed a box in living room...
  • 333rocky333
    333rocky333 replied to the thread Tail size 1980s.
    6mm or imperial equivalent tails from the henley block to a 30a switchfuse was quite common, I think even smaller stuff was used for...
  • 333rocky333
    333rocky333 replied to the thread JohnW2.
    John seemed very organised, when Harry bloomfield and EFLI was missing he said on that post QUOTE
  • 333rocky333
    333rocky333 replied to the thread JohnW2.
    Sad too hear, often private messaged him, but something he said only 2 months ago really moved me, when discussing previous members not...
  • 333rocky333
    Thinking about it proberly not, it was long ago I did it and i may have used 2.5mm it was flat like twin and earth i assume it was...
  • 333rocky333
    There's also an alternative version of the second drawing, by using 3 core and e from the rose to the switch and 4 core and e between...
  • 333rocky333
    The fan should be fused down and ideally double pole switched, likely where that black tape joint is you could replace with a...