Recent content by 62Joy

  1. 6

    Radiators constantly hot

    A heating engineer has called and said that it's two parts. One was leaking water and the part that turns the diverter valve had water in it. So the leak needs sorting and the other part needs replacing. He also said that my hot water is going into my radiators due to the fault, this is why...
  2. 6

    Radiators constantly hot

    Thanks for replying. That sounds like it's not physically turning a valve from hot water to central heating. Would that cause my problem?
  3. 6

    Radiators constantly hot

    My house is too hot due to the central heating being on, even though the control unit for my Ideal logic 24 combi is set to the off position. I have changed the batteries to two new Duracell batteries and switched the boiler mode selector to hot water only. Ironically, the central heating is...