Recent content by alex richards

  1. A

    Help required please - trying to swap randal 4033 timer with hive

    I have a y plan system with a honeywell 3 position diverter valve.. did my research
  2. A

    Help required please - trying to swap randal 4033 timer with hive

    This is the wiring for the 4033 that i was going off
  3. A

    Help required please - trying to swap randal 4033 timer with hive

    L on 4033 to L on Hive N to N E to E 2 to 4 4 to 3 5 to 1 if there was a wire in 5 There probably won't be a wire in 3 on the 4033 you shouldn't need a wire in 2 on the Hive. There was probably a link between 1 and L this can be discarded. thats how i wired it moving from the randall 4033 to...
  4. A

    Help required please - trying to swap randal 4033 timer with hive

    ok fair enough you are the experts i'm new to this really as just moved into my own house. im sure i checked the water and it did the same thing but ill recheck again after work.
  5. A

    Help required please - trying to swap randal 4033 timer with hive

    The timer/programmer...or hive call it rhe reciever unit. Na same thing you can just hear the pump working. Sorry i know it is confusing im confused.fish o_O
  6. A

    Help required please - trying to swap randal 4033 timer with hive

    this is what i went by an old thread from this site: L on 4033 to L on Hive N to N E to E 2 to 4 4 to 3 5 to 1 if there was a wire in 5 There probably won't be a wire in 3 on the 4033 you shouldn't need a wire in 2 on the Hive. There was probably a link between 1 and L this can be discarded...
  7. A

    Help required please - trying to swap randal 4033 timer with hive

    good evening everyone, I hope someone can help me i have recently bought a hive timer and thermostat and decided to try and replace the randal 4033 timer myself as it sounded pretty simple swapping over wires. I followed a wiring diagram off here off a previous post but i think ive gone wrong...
Back
Top