Recent content by AmzWag

  1. A

    22mm full bore braided hose

    For those that are connecting the water2buy 1 inch hose to an existing 3/4" stopcock that is already connected to a 22mm copper pipe, you will need a 1" male to 3/4" female reducing bush. I needed 4 of these bushes. 2 for the harveys water softener inlet and outlet connections, and 2 for the...
  2. A

    Galaxy G2-12 Part Bells & Night Bells

    Thank you Stuart, as always you are very helpful SME.
  3. A

    Galaxy G2-12 Part Bells & Night Bells

    Okay gents, so I've figured out what the issue is. Night set is activated and completed. The Front door contact and the Hall PIR are final zones . Someone enters from the front door. The 30 second entry time starts. After 30 seconds no pin code has been entered & the internal sounder goes off...
  4. A

    Galaxy G2-12 Part Bells & Night Bells

    Hi Alan. I commissioned the alarm at my mums house yesterday, it was a DIY install project. I will test both scenarios again this week. I've configured Night Set as: 1001 Main Door Contact FINAL 1002 Hall PIR FINAL 1003 Front Lounge PIR EXIT 1004 Kitchen PIR INTRUDER 1011 Rear Door Contact...
  5. A

    Galaxy G2-12 Part Bells & Night Bells

    Thanks alot Stuart, as always you are very helpful. Will give that a try. Regards. Amz
  6. A

    Galaxy G2-12 Part Bells & Night Bells

    Hi Folks Hope everyone is keeping safe during these testing times . I had a question about the part bells and night bells setting in 51 parameters. When the part set and night set has been activated and a zone is opened and the unsetting timer counts down from 30. If 30 seconds pass, only the...
  7. A

    Honeywell Galaxy Replacing PIR Sensors

    Just to report back that I managed to replaced the PIR by only removing the mains power and the Aux fuse. Aux fuse kills the power to all the sensors and keypads when removed. I kept the battery connected to stop the bell box from going off
  8. A

    Honeywell Galaxy Replacing PIR Sensors

    Hi, okay this makes sense, with the battery connected the shorting could blow the fuse. I have already prepared myself with 10 extra spare fuses in the event that I short & blow the AUX fuses.
  9. A

    Honeywell Galaxy Replacing PIR Sensors

    Hi, to replace the PIR I will need to remove all 6 wires from the sensor. I was hoping not to remove any wires from the panel, as I'm replacing 9 PIRs. Can you please kindly expand on the comment relating to removing the positive from the PIR? Thanks
  10. A

    i-ON 40 burglar alarm battery replacement

    Recently my house alarm was randomly going off in the night. It ended up being the front door reed magnet contact. For a couple of weeks I refused to set the alarm in case of waking up the whole street as it was going off in part, night and full set. Checking the resistance of the contact may...
  11. A

    Honeywell Galaxy Replacing PIR Sensors

    Hi Folks I needed some advice about the best way to go about replacing a PIR sensor. My steps were going to be: 1. Put the panel in engineer mode 2. Remove the mains power from the panel 3. Remove the F2 AUX 500ma glass fuse from the mainboard. My questions are: 1. Do I disconnect the...
  12. A

    Honeywell Galaxy Random Keypad Beeping In Part & Night Set

    Hi Alan, I am aware of putting the galaxy in engineer mode. What I need to know is if I need to remove the backup battery in addition to turning off the mains power and removing the Auxillary fuse when replacing pir sensors? Thanks AmzWag
  13. A

    Honeywell Galaxy Random Keypad Beeping In Part & Night Set

    Hi All Just to update to say thanks for the advice regarding the reed door contact. I have replaced the door sensor with a genuine Honeywell model. The resistance now reads 1007ohm closed and 2007ohm open. I am also replacing all of the pir sensors in the house. When I switch off the mains...
  14. A

    Honeywell Galaxy Random Keypad Beeping In Part & Night Set

    Thank you Stuart & Handymanjo The old contacts already have 2 X 1k ohm resistors. It's wired as shown in the below photo The zone status shows the below: 1001 open 13.71v 1975 ohm 1001 closed 13.71v 1032 ohm I am adding new resistors myself, 2 X 1k ohm. The Honeywell sensors are wired...
  15. A

    Honeywell Galaxy Random Keypad Beeping In Part & Night Set

    Hi Folks I just wanted to ask if the power needs to be turned off when replacing magnetic contacts? Presently there are only 2 wires connected to the contact and they feed into Zone 1001. I don't want to risk blowing a fuse on the panel due to shorting any of the cables in error. Thanks AmzWag