Recent content by andy28

  1. A

    Need help --been "cowboy'd"

    When you say both do you mean T the feed into behind the pump, then T the vent into the return. Then join both of them by T'ing the feed and vent so i have got a 'H' just above.
  2. A

    Need help --been "cowboy'd"

    so, looks like i need a 2 pipe system, seperate feed and seperate vent, just to be on the safe side. I have the 2 x 22mm pies coming from the boiler. On one i've got the pump so i would take this to be the flow side. After the pump both T off, going to the down stairs rads and upstairs to i...
  3. A

    Need help --been "cowboy'd"

    I know... Like i said, i can pipe up the header tank. Its just knowing where to take the vent and outlet to the heating side.
  4. A

    Need help --been "cowboy'd"

    Tried again all this morning. Mobile still switched off. Looks like he's long gone so have to put this one down to experience. A couple of others recommended to me are all booked up for weeks.
  5. A

    Need help --been "cowboy'd"

    Thanks for the link John. I shall eventually replace this old system with the old floor standing boiler for a combi. As things stand at home i can't do this until late spring when i will get the whole old system and rads ripped out. Hence making the repair to tide us over until then.
  6. A

    Need help --been "cowboy'd"

    I've done quite a few plumbing jobs now so will be OK. So it looks like i need to convert to an indirect cylinder and a header tank. Would someone talk me through how to install it. Obviously i use the cold tank which was above the primatic to supply the cold inlet at the bottom and...
  7. A

    Need help --been "cowboy'd"

    Well, i did as you guys suggested. Drained down OK and i have replaced the leaking valves either side of the pump. However, the problem lies with the cylinder. This morning it looked more imploded than last evening!! When i looked at the cold cistern i noticed that the vent pipe had been bent...
  8. A

    Need help --been "cowboy'd"

    Theres a valve either side of the pump. One of them is leaking and wont stop. The valve is like a gate valve but without the wheel on it. Wife says its leaking more since the plumber tried to fix the system. Primatic cylinder has got a huge dent in it. I have begun to fill it halfway but it...
  9. A

    Need help --been "cowboy'd"

    Guys is this what i need to do. Its cold tonight and need to try and begin to sort it.
  10. A

    Need help --been "cowboy'd"

    So, what i need to do is isolate the cold feed to the cold water cistern which i can see above the Primatic hot cylinder. Theres no valve on the cold inlet so i suppose i would turn off the cold at the main stopcock. Then open the hot taps and also open a drain off which i have found below a...
  11. A

    Need help --been "cowboy'd"

    Gas4you.....I dont have a small expansion tank for the heating side on this system. Its confused me cos i did in our last property. Its an old floor standing boiler in the kitchen (needs upgrading i know). Off the boiler are 2x22mm pipes running along the wall and into the old pantry. In...
  12. A

    Need help --been "cowboy'd"

    Need some help here. Just got in to find wife in floods of tears. This morning she noticed that the pump was leaking. She called a plumber who came out. She said he tried to tighten it up but made the leak worse, so told her he would drain down the system. After a hour he said he was leaving...