and yes i can check an aps however following fault diagnosis with ravenheat it led to gas supply valve unit was trying to ignite at the time. it also occasionally lit for about 30 seconds then went out
thanks tony
however you are in london and i am in bolton sometimes desparate measures are called for and i totally understand need for regulation however i will try and get a registered engineer to come out anfd look at boiler however it becomes very discouraging when i keep getting i don,t do...
thanks gas aid i totally agree however previous my previous post may go some way to explaining my actions most fitters i have contacted will not touch ravenheat and as boiler is only 2 years old i am reluctant to replace ( fitted before we moved in ) i have checked venturi and air pressure...
gas valve was replaced upon advice of ravenheat technician however i took his advice and the fact that my local suppliers have sold these in plentyful amounts. i understand your reluctance but i am fairly confident in my diagnosis and at 4 pm on a friday and difficulty in getting any body to...
Having gone through all ravenheat forums i do not seem to have found a proper answer to this problem.