    Method of fixing joists on a flat roof

    Question . If I worry about my L shaped straps on my wall plate can I add twisted straps to be on safe side ? Or is it pointless ?
  2. B

    Connect dpm to dpc in garage conversion

    There will be insulation under the floor . I will run the DPM up the wall and past the DPC. It seems maybe better not to seal it and trim the dpm at screed level . I will just need to make sure plasterboard is 25mm off floor level. So there is ventilation if there is actually any damp rising.
  3. B

    Dpc dpm worries

    Hello In my garage conversion , I can see the dpc. But it's trimmed against the wall . How do I connect the dpm to it before pouring screed/concrete ? Thanks
  4. B

    How to attach DPM to flush DPC

    So you don't trim it to floor level after concrete is poured ?
  5. B

    Connect dpm to dpc in garage conversion

    Hello In my garage conversion , I can see the dpc. But it's trimmed against the wall . How do I connect the dpm to it before pouring screed/concrete ? Do I just paint blackjack all around the wall under and over the dpc and then run up dpm and overlap it ? Thanks
  6. B

    Insulating the overhang of warm roof - what am I missing?

    how do you make that area air tight? do you paint VCL on the inside of that area? Or not bother?
  7. B

    Warm flat roof and ewi

    Hello I am still unclear if I need to make the space between the roof and the brick wall airtight? Do I paint some kind of liquid VCL membrane on the joists on the inside in this space?
  8. B

    Blue MDPE pipe

    I need to install a new water supply (32mm MDPE). In an ideal world, I would do it before laying my concrete floor but due to delays, I wonder if it's acceptable to use a duct and pull a MDPE pipe though at a later date? Is it difficult to pull the pipe? What about bends? Otherwise maybe I...
  9. B

    Warm flat roof and ewi

    Thank you. I don't need to put liquid VCL such as https://www.soudal.co.uk/pro/products/coatings/air-and-vapourtight-coatings/soudatight-lq ?
  10. B

    Warm flat roof and ewi

    Does the type of foam matter ? There's such a bewildering choice ....
  11. B

    Warm flat roof and ewi

    Do I need foil tape or is it sufficient to foam the joists at the edges? I imagine it's a bit of a faff to foil tape all the way around each joist.
  12. B

    Warm flat roof and ewi

    No. There is timber noggins between the joists at the edge. It's a small flat roof with 100mm x 47mm joists on top of a wooden wall plate . There is no cavities as it's a solid wall with Kingspan k5 on the exterior. I think I'm going to have to apply liquid membrane to make it all airtight...
  13. B

    Warm flat roof and ewi

    I am building an solid brick extension and have a warm flat roof . The joists overhangs a bit. Then there is a fascia board. The plan was to put ewi all the way up into the fascia boards in between the joists ( in hindsight I should have built it differently to avoid joists and cold bridge -...
  14. B

    Weep holes under dpc

    Some feedback! As per woody suspicion...it was indeed a drawing error by the structural engineer....
  15. B

    Weep holes under dpc

    Thanks . Solid single block construction. External insulation. No suspended floors . All solid . I haven't seen gas membrane mentioned - I think it's mentioned standard DMP. I'll have to check with the structural engineer.