    Heatslave 20/25 heavy smoke now wont run

    Nozzle looked in good nick no side wear on the jet. But I will get a new one today. CO2 - we cant get it to run to get a CO2 reading ? And yes he has. Thanks for the ideas
  4. B

    Which Pressure Washer

    Get the highest flow rate you can and a turbo jet. If you buy a little cheap one then it will be like cutting the lawn with a razor blade, does the job but will take hours. Second hand steam cleaner would be a good buy :wink:
  5. B

    Engineered floor is creaking

    Floor up, and make sure the T&G isn't warped as well depending on how it was stacked. measure wher you need the underlay.
  6. B

    Brown Leather Sofas...help wanted with furniture

    If you have a Crazy Macs near you they have a lot of insurance seconds in at the moment and you could save yourself a couple of grand
  7. B

    Heatslave 20/25 heavy smoke now wont run

    As I said oilman my mates been a plumber for years and carried out a number of new installs for some large hotels this year so hes pretty good. We also have a top of the range 0-300 psi glisarene filled bottom entery pressure gauge costing all of about £10 lol. I've got my own engineering...
  8. B

    Heatslave 20/25 heavy smoke now wont run

    Thanks will you might be right I will get my mate to try this in the morning as long as hes not snowed in :(. Set up at the mo at 130 psi and 6.5 on the mixture (as per the book). We thoiught about dropping the pressure down although I will have less BTU's it might get it going.
  9. B

    Tiles coming away from Wall. What can I do?

    First of all if I tile a bathroom I allways leave a couple of odd tiles under the bath (Worth a check). If you cant find any get a tile that matches as close as possible and remove a whole one from a place where it cant be seen or out of direct site. Replace the tile on the wall with the...
  10. B

    artex ceiling

    I've just doubled boarded a number of rooms in a shop I've just bought. The only problem with plaster is that when you come to the coving at the edge you lose the depth due to the artex. If you do plaster then PVA the ceiling in advance. Good luck
  11. B

    Heatslave 20/25 heavy smoke now wont run

    Oilman forgot to say that I fitted a new motor as well just in case :(. We cleaned the plates and when it first run it was heavy soot again but then started to clear and hen the boiler locked out :(
  12. B

    Heatslave 20/25 heavy smoke now wont run

    Just over 2 years old Started playing up 2 days ago by locking out. Last night started bellowing out black smoke, so I knocked it off. Spoke to my mate whos being doing oil central heating for years and he said most prob the pump. So we install a new pump set the pressure, and the...