Recent content by bogblock

  1. B

    Problem with a replacement room stat

    Right I've had the new stat on the bench and tested it. It seems to work OK. Once it's satisfied it stays that way until it calls again. Looks to me as though some condition is coming off the existing wiring to cause this problem. The wiring itself is a bit of a rat's nest, so I'll tidy...
  2. B

    Problem with a replacement room stat

    Thanks for the replies. Richard. What bothers me is that the pump starts at these ten minute intervals and it is in the airing cupboard next to the bedroom. I am a light sleeper. D. What target and actual temperatures are we talking about? When I noticed this happening, the room...
  3. B

    Problem with a replacement room stat

    Hello Richard Yes it's new. All the parameters should be at their factory default settings. Cheers Dave
  4. B

    Problem with a replacement room stat

    Morning all I recently moved into my present house which has a Danfoss 102E programmer. The room 'stat was a Switchmaster. Both these items are dated 1994, when the house was built. The roomstat had two wires connected. One is permanently live (when the programmer is set to heating on) and...
  5. B

    Recess for inset gas stove

    Thanks for the reply Richard. I will only be preparing the recess. The professionals will fit the fire. What’s a gas fired wood burning stove? The quotes round woodburning don't really stand out enough do they? Cheers Dave
  6. B

    Recess for inset gas stove

    Morning all Our daughter has recently had a new CH boiler installed in her home. The old back boiler occupied this space .... She wants to fit a gas fired 'woodburning stove' in its place. I have the task of preparing the hole into which it will fit. Any ideas what I should...
  7. B

    Unidaire warm air electric storage heater.

    Thanks for the reply Softus. Good idea to look at/for the room stat. By failing to start I mean that the fan which blows air through the heated blocks doesn't turn, but apparently this is intermittent. The heater elements seem to work OK. I'll try to have a look at it tomorrow...
  8. B

    Unidaire warm air electric storage heater.

    Hello all A neighbour has one of these units and the fan is intermittently failing to start. Once it does start it seems to run OK. Anyone out there with any experience of servicing these things? Cheers Dave
  9. B

    Worcester Bosch Danesmoor 12/15 problem

    Thanks for the replies folks Dave
  10. B

    Worcester Bosch Danesmoor 12/15 problem

    Evening all I recently recovered a balanced flue oil fired boiler from my garage. It worked OK and had been serviced so a neighbour bought it and fitted it in his house. It works OK until the cover goes on the burner to complete the 'room seal', when it stops and locks out. Neither of...
  11. B

    Driveway

    Have a look at http://www.pavingexpert.com/home.htm Cheers Bogblock
  12. B

    Electro Osmosis - DPC's

    Thanks for the BRE link Fred62. At £42 a copy it's worth a visit to the library. Please bear in mind that my original post asked for any experience of electro osmosis. I know of only one local installation, which apparently worked, given a few months to take effect. Anobium's comment about...
  13. B

    Electro Osmosis - DPC's

    Thanks anobium It would appear, after this long, that they are not very popular. I have looked through the forum and found hundreds of posts and a bewildering number of opinions. I'll have another look round. Cheers Bogblock
  14. B

    Electro Osmosis - DPC's

    Afternoon all. The theory looks good, but I'd like to know if it works in practice. Does anybody have any experience of this system?