Recent content by bozzy

  1. B

    No Hot Water Again on SwiftFlow 100 Boiler

    I have already replaced the flow switch once and all you have to remove is the front chamber cover then undo the pipe union and lock nut It's a bit fiddly but no need to remove the burner or anything else.
  2. B

    No Hot Water Again on SwiftFlow 100 Boiler

    OK, I upped the pressure slightly, and to my delight the boiler fired up when I turned on the hot water tap........Unfortunately my joy was short lived because when I turned the tap off the boiler did not shut down, not good, turned water back on and off again but no joy stuck solid. Shut...
  3. B

    No Hot Water Again on SwiftFlow 100 Boiler

    Sorry..... I didn't realise that you have to save each page individually Al done now...I hope :oops:
  4. B

    No Hot Water Again on SwiftFlow 100 Boiler

    Profile updated, Thanks Again
  5. B

    No Hot Water Again on SwiftFlow 100 Boiler

    Thanks for the info I will clean out the throttle and let you know how I get on
  6. B

    No Hot Water Again on SwiftFlow 100 Boiler

    I currently have only occasional Hot water from my Swiftflow 100 boiler i.e every now and then it will work. I have bypassed the DHW Flow switch with the water flowing and the boiler fires up no problem. I therefore assume the problem is with the DHW Flow switch although the water pressure...
  7. B

    Gloworm SwiftFlow 100 no Hot Water

    One last question, can I remove the reed switch without isolating the water supply? Thanks Again
  8. B

    Gloworm SwiftFlow 100 no Hot Water

    Thanks Nickso, Now I'm concerned :x the rattling I mentioned sounds like somthing metallic in the pipe around the flow switch, could this indeed be the magnety bit you mention. I assume the magnet comes with the complete flow switch? Thanks Again
  9. B

    Glowworm Swftflow 100

    I have a SwiftFlow 100 and as Micky says the fan runs constantly to vent the pilot and as a result will probably fail at some point costing over £120 to replace.. No I'm not bitter :twisted:
  10. B

    Gloworm SwiftFlow 100 no Hot Water

    Thanks Tony I just didn't want to fork out £67 for nothing :( If anyone knows where I can get a flowswitch (800136) cheaper please let me know. Many Thanks
  11. B

    Gloworm SwiftFlow 100 no Hot Water

    Hi I have a GlowWorm SwiftFlow 100 which no longer produces Hot Water. When I run the hot water tap I get a loud rattling clicking sound from the left hand side of the boiler which it has always done to a certain extent but this sound used to go away once the boiler fired up, almost as if the...
  12. B

    Glow Worm SwiftFlow 100 Pressure increasing

    I drained the Boiler pumped up the expansion vessel, re-pressurised and whoopee no pressure increase Thanks to everyone but I know have another problem Heating working perfectly but the hot water won't kick in. When I turn on the hot tap I get a loud clicking from the boiler but no green...
  13. B

    Glow Worm SwiftFlow 100 Pressure increasing

    Thanks for the info people, could someone just advise me of the proper procedure to drain the boiler, Much Appreciated
  14. B

    Glow Worm SwiftFlow 100 Pressure increasing

    Thanks Mick but to add to my previous post the pressure does not increase whilst the boiler is off, the pressure only increases whilt the boiler is running. I assume if it was the fill loop the pressure would rise consistantly boiler on or off? Yesterday morning pressure was at .5bar this was...
  15. B

    Glow Worm SwiftFlow 100 Pressure increasing

    I Have a Glow Worm SwiftFlow 100 and the pressure slowly increases throughtout the day with me ending up releasing the pressure via a radiator blead valve, as far as I can tell the fill tap is closing properly so I don't think it is that because whenever the fan is running at full speed you hear...